    SITS-120 Secondary Injection Test Set

    SITS-120 Secondary Injection Test Set

    Harga:
    Hub :021- 32375508
    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat

    Keterangan :

    SPECIFICATIONS
    Input Power
    120 or 240 Vac ( specify one) ± 10% , 50/ 60 Hz
    Outputs
    Two indenpendently controlled adjustable outputs are available
    from the test set, one ac current and one ac/ dc voltage. The
    voltage output can be operated either simultaneously or
    independently from the current output.
    Output Current
    Continuously adjustable in the following ranges:
    Output Current Full Load Voltage
    0 - 5 Amperes 140 Volts
    0 - 10 Amperes 70 Volts
    0 - 25 Amperes 28 Volts
    0 - 120 Amperes 5 Volts
    When the voltage is sufficient to push higher than rated current
    through the load, the current ratings listed in the table can be
    exceeded for short duration’ s.
    Duty Cycle
    Maximum time on is 5 minutes followed by 15 minutes off.
    Short time overloads are possible.
    AC Voltage Output ( Switch Selected)
    Output Voltage Current Rating
    0-240 Volts 2 Amp
    DC Voltage Output ( Switch Selected)
    Output Voltage Current Rating
    0-240 Volts 1 Amp
    Metering
    Measured quantities such as AC Current, AC Voltage, DC Voltage
    and Time are displayed on large, LED displays. The
    Ammeter/ Voltmeter is a dual purpose meter, whose function is
    switch selected. When selected as a voltmeter it will measure
    either ac or dc depending on the selector switch.
    AC Ammeter ( Switch Selected)
    Ranges and Resolution: 0 to 1.999/ 19.99/ 199.9/ 400 Amperes
    Accuracy: ± 1 % of range
    Measurements: True RMS, Continuous Mode. Peak Hold in
    Memory Mode
    AC Voltmeter ( Switch Selected)
    Ranges and Resolution: 0 to 1.999/ 19.99/ 199.9/ 400 Volts
    Accuracy: ± 1 % of range
    Measurements: True RMS
    DC Voltmeter ( Switch Selected)
    Ranges and Resolution: 0 to 1.999/ 19.99/ 199.9/ 400 Volts
    Accuracy: ± 1 % of range
    Measurements: Average
    Timer
    Display: Five ( 5) digits
    Ranges and Resolution: Seconds and cycles with the following
    range and resolution ( switch selected) :
    Seconds: a) 0 to 999.99
    b) 0 to 99.999
    Cycles: 0 to 99999
    Accuracy: ± least significant digit or ± 0.005% of reading
    whichever is greater.
    Start/ Stop/ Monitor Gate
    Two identical, independent, Start, Stop or Monitor Gate circuits
    are provided. To monitor operation of relay contacts or trip SCR, a
    continuity light is provided for the Stop gate. Upon sensing
    continuity the monitor lamp will glow and a tone generator will
    sound.
    The following modes are provided for the Start, Stop/ Monitor Gates:
    1. Timer will start, stop or continuity indicator darkens at the
    opening of normally closed contacts or when conduction
    through a semiconductor device such as a triac or transistor is
    interrupted.
    2. Timer will start, stop or continuity indicator glows at the closing
    of normally open contacts or upon conduction through a
    semiconductor device such as a triac or transistor.
    3. Timer will start, stop or continuity indicator glows or darkens
    upon the application or removal of either an ac or dc voltage
    ( 60 to 300 Vac) , ( 5 to 300 Vdc) . The maximum voltage to be
    applied is 300 Volts ac or dc.
    4. Starting or Stopping with any selected output. The Timer can
    be started or stopped when turning on or off any ( or all)
    selected outputs.
    5. In the Current Accurate Mode the Timer stops when output
    current is interrupted.
    Start Latch: The Timer Start Gate is provided with a latch
    feature which allows timing to be initiated by a Start Gate and
    to be stopped only by the selected Stop Gate. When
    unlatched, the Start Latch allows timing to be stopped when
    the Start Gate is reversed ( such as when timing the closing and
    opening of a single contact as in measuring the trip-free
    operating time of a circuit breaker) .
    Stop Latch: The Timer Stop Gate latch feature which allows
    timing to be stopped at the first operation of any Stop Gate
    ( thus ignores contact bounce) . When unlatched, the Stop Latch
    allows timing to be stopped by any Stop Gate and then
    restarted if the Stop Gate reverses ( provided a Start Gate is still
    energized) , and then stopped again when the gate reverses
    ( total time including contact bounce) .
    Protection
    Input and outputs are protected from short circuits and prolonged
    overloads.
    Anciliary Interface
    A voltage signal output, in phase with the main current output, is
    provided to input into the EPS-1000A or PVS-1000 for phase
    reference. This will allow testing of more complex relays which
    require phase shifting bewtween a three-phase voltage output and
    a current output.
    Enclosure
    The unit comes mounted in a rugged plastic transit case for field
    portability. The tongue and groove lid protects the unit from rain
    and dust intrusion. Spring loaded carry handles are located on
    each side.
    Temperature Range
    Operating: 32 to 122° F ( 0 to 50° C)
    Storage: - 40 to + 158° F ( - 40 to 70° C)
    Dimensions
    11 H x 15 W x 12 D in. ( 281 H x 383 W x 306 D mm)
    Weight
    47 lb ( 21.4 kg)