    Technical Specifications
    Power quality measurement standards
    Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
    Clock/ calendar Leap years, 2 4-hour clock
    Real-time clock accuracy Not more than ± 1 s/ day
    Internal memory capacity for data At least 2 GB
    Maximum recording period At least 31 days
    Measurement time control Automatic
    Maximum number of events Limited only by the size of the internal memory
    Power requirements 100 to 2 40 V rms ± 10 % , 47-63 Hz, 40 W
    Operating time during interruptions ( internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging
    Dimensions 215 mm x 310 mm x 35 mm ( 8.5 in x 12.2 in x 3.5 in)
    Mass ( weight) 6.3 kg ( 14 lb)
    Input
    Measurement types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/ 2 Element Wye
    Input channels Voltage: 4 channels, ac/ dc
    Current: 5 channels
    Voltage channels Input resistance: 2 M©
    Input capacitance: < 2 0 pF
    Current input characteristics 2 V rms = full scale, 1 M© Input Impedance for ferro CTs, low impedance for Flexi-CTs
    Measuring method Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops.
    Synchronization and sampling
    PLL-synchronization source The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta.
    PLL lock range 42.5 to 69 Hz
    Sampling frequency Voltage and current: 2 56 samples/ cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/ 10 cycles ( 50 Hz) , 3072 points/ 12 cycles ( 60 Hz) Transient Voltage: 5 MHz
    A/ D resolution Voltage and current: 2 4 bits
    Transient voltage: 14 bits
    Voltage and current measurements
    Voltage measurement range AC voltage: 1000 V rms ± 10 % over range
    DC voltage: ± 1000 V + 10 % over range
    Voltage crest factor 3 or less
    Current measurement range Depends on current probe used
    Current crest factor 4 or less
    RMS voltage
    Measurement type True rms calculated continuously: every cycle, every 1/ 2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
    Measurement uncertainty AC: ± 0.2 % reading ± 0.1 % full scale, above 50 V rms
    DC: ± 0.5 % reading ± 0.2 % full scale, above 50 V dc
    RMS current
    Measurement type True rms calculated continuously: every cycle, every 1/ 2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Transient voltage ( impulse)
    Measurement type Waveshape sampling
    Full scale 8000 V pk
    Sample resolution 200 nS
    Measurement uncertainty ± 5 % reading ± 2 0 V ( test parameters: 1000 V dc, 1000 V rms, 100 kHz)
    Voltage swell ( rms swell)
    Measurement type True rms ( one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data Amplitude and duration of swell
    Measurement Same as rms voltage
    Voltage dip ( rms sag)
    Measurement type True rms ( one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data Amplitude and duration of dip or interruption
    Measurement Same as rms voltage
    Voltage dropout ( interruption)
    Measurement type Same as voltage dip
    LAN interface
    Connector RJ-45
    Speed and type 10/ 100 Base-T, auto MDIX
    Communications protocol TCP/ IP over Ethernet
    Wireless controller interface
    Connection wireless ( 2.4 GHz radio)
    Speed up to 700 kbit/ second
    Communications protocol Bluetooth SPP

    Power Measurements
    Power, battery life
    Measurement type True rms calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Frequency
    Measurement range 42.5 to 69 Hz
    Measurement source Same as PLL synchronization source
    Measurement accuracy ± 10 mHz ( 10 to 110 % of range, with sine wave)
    Power Factor
    Measurement range 0.000 to 1.000
    Measurement accuracy ± 1 digit from the calculation of each measured value ( ± 3 digits for total)
    Displacement power factor
    Measurement method Calculated from the phase difference between voltage fundamental and current fundamental
    Measurement range - 1.000 ( leading) to + 1.000 ( lagging)
    Measurement accuracy ± 0.5 % reading ± 2 % full scale ± 1 digit
    Voltage unbalance and phase sequence
    Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
    Harmonic voltage and current
    Analysis window rectangular
    Analysis order 1st to 50th order
    Measurement accuracy Voltage / Current: 1st to 2 0th orders: ± 0.5 % reading ± 0.2 % full scale, 2 1st to 50th orders: ± 1 % reading ± 0.3 % full scale ( current sensor accuracy must be included for current and power)
    Measurement method IEC 61000-4-7
    Inter-harmonic voltage and current ( intermediate harmonics)
    Analysis window rectangular
    Analysis orders 1.5 to 49.5th order
    Measurement method IEC 61000-4-7
    Flicker
    Measurement method IEC 61000-4-15
    Plt for 2 hours and PSt for 10 minutes
    Measuring range: 0, 1 to 5 ( 25) depending on voltage level, modulation and frequency
    Environmental Specifications
    Environmental
    Operating environment Indoors or in covered area outdoors, up to 2 000 m altitude
    Storage temperature and humidity -20 ° C to 50 ° C, 80 % RH max, non-condensing
    Operating temperature and humidity 0 ° C to 40 ° C, 80 % RH max, non-condensing
    Maximum rated working voltage
    Voltage terminals 1100 V rms
    Voltage durability 5550 V rms ac for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case ( 50/ 60 Hz, 1 mA sense current)
    Enclosure protection IP30 ( per EN 60529)
    Standards:
    EMC EN 61326-1: 1997+ A1: 1998 Class A EN 61000-3-2: 1995+ A1: 1998+ A2: 1998
    EN 61000-3-3: 1995
    Safety EN 61010-1 2 nd Edition; 2 000
    Voltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV ( anticipated overvoltage: 8000 V)