    Thermostat Digital Dixxel( Spare-parts Walk in chiller-Freezer-Showcase)

    Thermostat Digital Dixxel( Spare-parts Walk in chiller-Freezer-Showcase)

    Harga:
    BERVARIASI
    Jumlah Pesanan:
    Cara Pembayaran:
    Tunai
    Kemas & Pengiriman:
    Baru

    Keterangan :

    Jayco Teknik Mandiri
    Perbaikan Dan Pengadaan Spare parts Mesin Semua Jenis Mesin Pendingin Al:

    Menyediakan Dan Pemasangan Kontrol Electrical Walk in-Chiller-Freezer-Showcase al:
    -Thermostat Digital
    -Timer Defrost-Paragon, dll
    -Contactor Magnetic
    -HLPS ( High Low Pressure Switch)
    -OLPS ( Oil Pressure Switch)
    -Selonoid Valve
    -Oil Separator

    Tersedia Control Thermostat Digital DIXXEL
    Spesifikasi Sebagai Berikut:
    Display 3 digits, d.p., -
    Power supply 12, 24Vac/ dc
    110, 230Vac
    Inputs
    Probe NTC / PTC
    Measurement
    Measurement range probe dependent
    Accuracy Better than 1% of full scale
    Generals
    Housing Self extinguishing ABS
    Front protection IP65 with gasket
    Display type red LED ( 13.2mm high)
    Data Storage EEPROM memory
    Operating temperature 0° ÷ 60° C
    32° ÷ 140° F
    Storage temperature -30° ÷ 85° C
    22° ÷ 185° F
    Relative humidity 20÷ 85%
    Resolution 0.1° C or 1° F
    Connection Screw-terminal block

    SETTING DIXXEL CONTROL

    Dixell Digital Controls
    Many Oscartielle cases utilize an electronic control board with digital thermometer / thermostat, providing:
    • Temperature accuracy.
    • Programmable defrosting.
    • Diagnostic capability ( eliminating need for mechanical defrost clocks) .
    Please Note: These are Low Temp Control Setting Instructions for Oscartielle Gelato & Ice Cream Showcases
    To Check Temperature Setting:
    1. Press and hold in the set button for 5 seconds to see the temperature setting
    2. To adjust the temperature setting use the up or down arrow
    3. * * normal setting is 4 degree F
    4. After checking or changing the temperature setting - press the set button
    To Check All Parameters:
    1. Press and hold in the down arrow and set
    2. Button together for 5 seconds till you see HY – release both buttons
    3. Press the down arrow 1 time till you see PR2
    4. Press set and you will see PA5
    5. Press set and you will see a flashing zero
    6. Press the up arrow 3 times till you see 3
    7. Press set and you will see the 2nd flashing zero
    8. Press the up arrow 2 times till you see 2
    9. Press set and you will see the 3rd flashing zero
    10. Press the up arrow 1 time till you see 1
    11. Press set
    You Will Now See HY:
    1. Press set and you will see the setting for HY
    2. To change a setting use up or down arrow
    3. Press set and you will see the next parameter
    4. Then press set to check that setting
    5. continue to press set one time to move to next parameter
    6. And then set again to check that parameter
    From HY:
    If you just want to check a certain parameter, use the up or down arrow till you see the one you want to check. Then press set to check that parameter.
    After checking or changing the parameters – wait for 10 to 15 seconds and the control will reset and go back to reading the case temperature.
    Label Parameter Description Range Value Menu
    Set Set point LS ÷ US 4 ---
    Hy Hysteresis 0.1 ÷ 25.5 ° C / 1 ÷ 45 ° F 3 Pr1*
    LS Minimum Setpoint -50.0° C ÷ SET / -58° F ÷ SET -22 Pr2
    uS Maximum Setpoint SET ÷ 110° C / SET ÷ 230° F 80 Pr2
    odS Outputs activation delay at startup 0 ÷ 255 min. 0 Pr2
    Ac Anti-short cycle delay 0 ÷ 30 min. 1 Pr1^
    con solenoid valve on time with faulty probe 0 ÷ 255 min. 15 Pr2
    coF solenoid valve off time with faulty probe 0 ÷ 255 min. 30 Pr2
    cH Governor type of action cL / Ht cL Pr2
    cF Temperature measurement unit: Celsius, Fahrenheit ° C / ° F ° F Pr2
    rES Resolution ( integer/ decimal point) in / de In Pr2
    Lod Local display P1 / P2 / P3> P1 Pr2
    tdF Defrost type rE / in in Pr2
    EdF Defrost mode rtc / in / Sd In Pr2
    SdF Set point for SMART DEFROST -30 ÷ + 30 ° C / -22 ÷ + 86° F 0 Pr2
    dtE Defrost termination temperature -50.0 ÷ 110.0 ° C / -58 ÷ 230 ° F 45 Pr1^
    idF Interval between defrost cycles 1 ÷ 120 ore 6 Pr1^
    MdF ( Maximum) length for defrost 0 ÷ 255 min. 15 Pr2
    dFd Displaying during defrost rt / it / SEt / dEF / dEG rt Pr2
    dAd Max display delay after defrost 0 ÷ 255 min. 0 Pr2
    Fdt Draining time 0 ÷ 255 min. 5 Pr2
    dPo First defrost after start up no / Yes n Pr2
    dEM End defrosting global mode ALL / Loc Loc Pr2
    Fnc Fans operating mode C-n/ c-y/ O-n/ O-y O-n Pr2
    Fnd Fans delay after defrost 0 – 255 min. 1 Pr2
    Fst Fans stop temperature 120 Pr2
    ALc Temperature alarms configuration: relative/ absolute rE / Ab Ab Pr2
    ALu Maximum temperature alarm -50.0 ÷ 110.0 ° C / -58 ÷ 230 ° F 170 Pr2
    ALL Minimum temperature alarm -50.0 ÷ 110.0 ° C / -58 ÷ 230 ° F -40 Pr2
    AFH Temperature alarm and fan hysteresis 0.1 ÷ 25.5 ° C / 1 ÷ 45 ° F 2 Pr2
    ALd Temperature alarm delay 0 ÷ 255 min. 15 Pr2
    dAo Delay of temperature alarm at start up 0 ÷ 23h 50 min. 1.3 Pr2
    EdA Alarm delay at the end of defrost 0 ÷ 255 min. 30 Pr2
    dot Alarm delay after closing of the door 0 ÷ 255 min. 30 Pr2
    ot Thermostat probe calibration -12.0 ÷ + 12.0 ° C / -21 ÷ 21° F 0 Pr1*