Keterangan :
Product/ Chemical Name: Linear alkyl benzene Sulphonic Acid ( LABSA96% )
INCI Name: Linear alkyl benzene Sulphonic Acid
Other Designations: Benzenesulphonic acid, C10-16-alkylderives
Chemical Formula: CH3. ( CH2) 11 C6H4 SO3 H ( Product by Reaction Between SO3 Gas and LAB )
Compony Address
Factory: Royal Chemicals Company
Industrial-area
Port-said,
Egypt
Royal Chemicals contacts:
Fax: 0020 2 24025660
Mob: 002012 0273021
Export manager: Mr. Amir Aziz
2.Composition / Information on Ingredients
Pre-registration # 05-2115592308-38-0000
CAS Number# 68584-22-5
C10-16-alkylbenzene sulfonic acid
Benzene, C10-16- alkyl derives
Sulfuric acid
Trace Impurities: Sulfur dioxide 7446-09-5, 0.1%
3.Hazards Identification
* * * * * Emergency Overview * * * * *
Potential Health Effects
Primary Entry Routes : inhalation, ingestion, eye and skin contact
Acute Effects
Inhalation : Breaching of SO2 vapors may cause a gradual burning feeling resulting in irritation, reddening and possible chemical burns.
Eye : irritation, reddening, and possible chemical burns .
Skin : Contact with skin will cause a gradual burning feeling resulting in irritation, reddening and possible chemical burns. Prolonged and repented contact will cause deoiling of the skin resulting inflammation rashes or dermatitis.
Ingestion : swallowing material may cause burning feeling resulting in irritation, reddening and possible chemical burns to the mouth, throat, and muccus membrane . Material may cause sickness and upset stomach.
Carcinogenicity : OSHA do not list lineer Alkyl Banzine Sulfonic Acid as a carcinogen.
Section 4 – First Aid Measures
Inhalation: move away from vapors to fresh air source
Eye contact: wash eyes immediately with running water. Including under the eyelids for 15 mins
Skin contact: wash area with running water 5 to 10 mins .contaminated clothing should be washed before reuse
Ingestion: give 2 to 3 cups of dilute sodium carbonate or bicarbonate solution to drink. Do not induce vomiting after first aid .get appropriate in – plant .paramedic . or community medical support.
Note to physicians: there is no specific antidote. Treatment of overexposure should be directed at the control of symptoms and or vomiting. There may be lung injury. Therefore .nemesis should not be induced by mechanical or pharmacological means if it is considered that evacuation of the stomach contents is necessary.
Section 5 – Fire – Fighting Measures
Flash point : > 300 c
Flash point method: TOC
Extinguishing media: water. form , co2. Or dry chemical
Unusual fire or Explosion Hazards: none
Hazardous combustion products: oxides of carbon sulfur containing hydrocarbons, hydrocarbons and soot
Fire – Fighting Instructions : Do not release runoff form fire control methods to sewers or waterways.
Fire – Fighting Equipment : because fire may produce toxic thermal decomposition products . wear a self – contained breathing apparatus ( SCBA) with a full face piece operated in pressure-demand or positive – pressure mode .