Selamat Datang di
PT HAS ENVIRONMENTAL

Anggota Gratis
PT HAS ENVIRONMENTAL
PT HAS ENVIRONMENTAL
Indonesia
  • Katalog Produk

    Blasmate III

    Blasmate III

    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Transfer Bank (T/T)

    Keterangan :

    BLASMATE III

    Fungsi :
    Untuk mengukur tingkat getaran pada proses peledakan / blasting.

    Aplikasi :
    - Perusahaan Pertambangan
    - Institusi Pemerintah
    - Pabrikasi ( manufacturing)
    - Laboratorium K3 dan Lingkungan
    - Institusi Pendidikan dan Penelitian

    Spesifikasi :
    * Channels : Microphone and Triaxial Geophone or 4 independent user configurable channels ( two microphones and two Triaxial Geophones or 8 independent channels with optional 8 channel upgrade )

    * Vibration Monitoring ( with Standard Triaxial Geophone )
    Range : Up to 254 mm/ s ( 10 in / s )
    Resolution : 0.127 mm/ s ( 0.005 in/ s) or 0.0159 mm/ s ( 0.000625 in/ s) with built in preamp
    Accuracy : ± 5% or 0.5 mm/ s ( 0.02 in/ s) , whichever is larger, between 4 and 125 Hz / DIN 45669-1 standard
    Transducer Density : 2.13 g/ cc ( 133 lbs/ ft3)
    Frequency Range : 2 to 250 Hz, within zero to -3 dB of an ideal flat response / 1 to 315 Hz

    * Air Overpressure Monitoring
    Weighting Scales : Linear or A Weight
    Linear Range : 88 to 148 dB ( 500 Pa ( 0.072 PSI ) Peak )
    Linear Resolution : 0.25 Pa ( 0.0000363 PSI )
    Linear Accuracy : + / - 10% or + / - 1 dB, whichever is larger, between 4 and 125 Hz
    Linear Frequency Response : 2 to 250 Hz Between -3 dB roll off points
    A -Weight Range : 50 to 110 dBA
    A-Weight Resolution : 0.1 dBA
    Maximum Cable Length ( ISEE / DIN ) : 75 m ( 250 ft ) / 1, 000 m ( 3, 280 ft )

    * Waveform Recording
    Record Modes : Manual, Single shot, Continuous
    Seismic Trigger : 0.125 to 254 mm/ s ( 0.005 to 10 in/ s)
    Acoustic Triggers Linear : 100 to 148 dB A Weight : 55 to 110 dBA

    * Sample Rate : 1.024 to 16, 000 S/ s per Channel ( independent of record time ) up to 65, 000 S/ s
    in single channel mode with advanced software ( maximum 8, 000 S/ s per channel for 8 channels )

    * Record Stop Mode : Fixed record time, Instantel Auto Record , record stop mode

    * Record Time : 1 to 100 seconds ( programmable in one second steps ) or 500 seconds plus 0.25 seconds pre trigger

    * Auto Record Time : Auto window programmable from 1 to 9 seconds, plus a 0.25 second pre trigger. Events is recorded until activity remains below trigger level for duration of auto window, or until available memory is filled

    * Cycle Time : Recording uninterrupted by event processing - No dead time

    * Storage Capacity Full Wavefrom event : 300 one second events at 1, 024 S/ s sample rate ( 1, 500 event capacity with optional memory upgrade )
    Event Summaries : 1, 750 ( 8, 750 event capacity with memory upgrade )

    Histogram Recording

    * Record Modes : Histogram and Instantel Histogram Combo ( monitor captures triggered waveforns while recording in Histogram mode )

    * Recording Intervals : 2, 5 or 15 seconds; 1, 5 or 15 minutes

    * Storage Capacity : 46, 656 intervals 3 days at 5 second intervals or 102 days at 15 minutes intervals ( with memory up grade 15 days at 5 second intervals or 540 days at 15 minutes intervals )
    Physical Specifications

    * Dimensions : 269 x 355 x 165 mm ( 10.6 x 14.0 x 6.5 in )

    * Weight : 6.4 Kg ( 14 Lbs )

    * Battery : Rechargeable 6 V sealed gel cell capacity for 30 days of continuous monitoring

    * User Interface : 63 domed tactile keys including full keyboard and dedicated keys for common fucntions.