Selamat Datang di
CV. PELANGI TEKNIK

Anggota Gratis
CV. PELANGI TEKNIK
Indonesia
  • Katalog Produk

    KENWOOD CS-5405,  CS-5450,  CS-5455

    KENWOOD CS-5405, CS-5450, CS-5455

    Harga:
    Calll For Pricing
    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Transfer Bank (T/T)
    Kemas & Pengiriman:
    Unit

    Keterangan :

    Kenwood CS-5400 Series Oscilloscopes
    Models CS-5400, CS-5405, CS-5450, CS-5455

    All position knobs and controls are provided on the front panel.
    A High-sensitivity X-Y function is convenient for the measurement of phase differences between two input signals.
    A Trace Rotation function allows an easy correction of the inclination of the trace line due to earth magnetism.
    Line Synchronization is provided.
    A Trace Separation function shifts the B sweep waveform upward or downward by 4 div. from A sweep waveform.
    The waveform to which the brightness modulation is applied can also be observed.
    Added or subtracted waveforms using ADD and CH2 INV functions can also be observed.
    Scale illumination convenient for taking photographs or observation in dark areas is provided.
    CRT scale also provides 0, 10, 90 and 100% indications convenient for measurement of rising time, etc.
    A 10-times sweep waveform magnification function ( X10 MAG) is provided.

    Click here for larger image of the Kenwood CS-5400 Series OscilloscopesClick here for larger image
    Kenwood CS-5400 Shown

    Product Information
    Datasheet 160 KB
    Specifications HTML
    Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
    PDF Help

    The CS-5400 Series are 3-Channel oscilloscopes developed with concepts of high level design, high accuracy and easy operation. The panel layout never diminishes the intuitive and high-speed response provides fatigue free operation even after long-hours of use. These models incorporating readout function ( with CS-5400/ 5470/ 5450) offer you parameter measurement and auto setup functions enabling to measure AC voltage ( Vp-p) , DC voltage, frequency and period. All of these models are provided with full features including ± 2% high-accuracy measurement, delay sweep function, automatic triggering and high intensity, high-resolution CRT. The CS-5400 Series with high-performance will surely assist you in many kinds of field activities.

    CS-5400/ 5470/ 5450 FEATURES

    Parameter Auto Measurement Function

    It is possible to measure the voltage, frequency and period automatically - just input the signal. Especially for voltage measurement, measurement mode is automatically selected according to the input selector. For example, when the AC input is selected, " Peak-to-Peak" voltage is automatically measured, and when the DC input is selected, DC voltage is measured automatically.

    Auto Setup Function

    By pressing the AUTO SET key, the voltage range and time range are selected automatically.

    Cursor Measurement Function

    The cursor measurement function allows a high accuracy measurement of signal values. When the probes are used, its attenuation ratio can be converted automatically. It is also possible to measure the voltage value and phase differences. When the delay sweep is used, the delay time is also displayed, enabling accurate measurement results without any errors due to visual checks in conventional systems.

    Peak to Peak Voltage Measurement

    Parameter automatic measurement function enables automatic AC peak to peak voltage measurement up to 5MHz.

    Variable Lock

    ON/ OFF the vertical and horizontal variable functions can be set when pressing the ALT/ CHOP knob more than 1-second. When OFF is selected, it becomes CAL level. When the function is ON, it returns to prior value.

    CS-5400 SERIES COMMON FEATURES

    3-Channel 8-Trace Waveform Display

    CS-5400 series enable the display of CH3 input in addition to CH1 and CH2. These three input signals to CH1, CH2 and CH3 can be displayed at the same time as the main ( A) sweep waveform.

    Furthermore, an alternated delay sweep function displayed as the delayed ( B) sweep waveforms of each signal.

    High-Sensitivity Design with Vertical Axis of 1 mV/ div

    The vertical axis sensitivity can be varied continuously from 1 mV/ div to 5 V/ div using the 1-2-5 step attenuator. The 1 mV/ div position is very useful to measure low-level and complicated signals. [ Frequency response at 1 mV/ div and 2 mV/ div is DC to 20 MHz ( -3 dB) ] .

    Automatic Sync ( FIX) Function

    With this function, the synchronization level is automatically controlled by tracking the amplitude of the waveform to maintain the sync lock status. This function eliminates annoying and complicated synchronization operations.



Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.com. Hak Cipta Dilindungi Undang-undang.