PHOTO-RADIOMETER HD2302.0, Merk : DeltaOhm[1 Jul. 2009, 21:02:37]
Keterangan
The HD2302.0 is a portable instrument with a large LCD display. It measures illuminance, luminance, PAR and irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).The probes are fi tted with the SICRAM automatic detection module: in addition to detection, the unit of measurement selection is also automatic. The factory calibration settings are already memorized inside the instruments.The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be disabled.The instruments have IP67 protection degree.
INSTRUMENT TECHNICAL CHARACTERISTICS
Instrument Dimensions (Length x Width x Height) 140x88x38mm
Weight 160g (complete with batteries) Materials ABS
Display 2x41D2 digits plus symbols - 52x42mm
Visible area: 52x42mm
Operating conditions
Operating temperature -5…50°C Warehouse temperature -25…65°C Working relative humidity 0…90%RH without condensation
Protection degree IP67
Power Batteries 3 1.5V type AA batteries
Autonomy 200 hours with 1800mAh alkaline batteries
Power absorbed with instrument off 20¼A
Measuring unit lux - fcd - µmol/m2.s - cd/m2 - W/m2 - µW/cm2
Connections Input module for the probes 8-pole male DIN45326 connector
The probe LP 9021 ERY measures the total effective irradiance (Weff/m2) according to the UV action curve (CEI EN 60335-2-27). A particular type of photodiode and a combination of special fi lters bring the spectral response closer to the UV action curve.CEI EN 60335-2-27 standards estabilish a maximum allowable dose of 100J/m2 for fi rst-time exposure and an annual dose of 15000J/m2.The typical spectral response curve of LP 9021 ERY is shown in the Figure together with the UV action curve.The good accordance between the two curves enables the instrument to take reliable measurements of different types of lamps (and fi lters) used at present for tunning machines.Each probe is individually calibrated at DeltaOhm photo-radiometry laboratory by means of a double monochrome. Calibration is performed at 290 nm through a SIT calibrated reference photodiode.
ORDER CODES
HD2302.0K: The kit is composed of the instrument HD2302.0, 3 1.5V alkaline bat-teries, operating manual, case. The probes must be ordered separately. Probes complete with SICRAM module
LP 471 PHOT: Photometric probe for ILLUMINANCE measurement complete with SICRAM module, spectral response in agreement with standard pho-topic vision, diffuser for cosine correction. Measurement range: 0.01 lux…200Å103 lux.
LP 471 LUM 2: Photometric probe for LUMINANCE measurement complete with SICRAM module, spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 0.1 cd/m2…2000Å103 cd/m2.
LP 471 PAR: Quantum radiometric probe for the measurement of the photon fl ow across the chlorophyll range PAR (Photosynthetically Active Radiation 400nm…700nm) complete with SICRAM, measurement in ¼mol/m2s, dif-fuser for cosine correction. Measurement range: 0.01¼mol/m2s…10Å103¼mol/m2s.
LP 471 RAD: Radiometric probe for IRRADIANCE measurement complete with SICRAM module; in the 400nm…1050nm spectral range, diffuser for cosine correction. Measurement range: 0.1Å10-3W/m2 …2000 W/m2.
LP 471 UVA: Radiometric probe for IRRADIANCE measurement complete with SICRAM module; in the 315nm…400nm, peak 360nm, UVA spectral range, quartz diffuser for cosine correction. Measurement range: 0.1Å10-3W/m2…2000 W/m2.
LP 471 UVB: Radiometric probe for IRRADIANCE measurement complete with SICRAM module, in the 280nm…315nm, peak 305nm, UVB spectral range, quartz diffuser for cosine correction. Measurement range: 0.1Å10-3W/m2…2000 W/m2.
LP 471 UVC: Radiometric probe for IRRADIANCE measurement complete with SICRAM module, in the 220nm…280nm, peak 260nm, UVC spectral range, quartz diffuser for cosine correction. Measurement range: 0.1Å10-3W/m2…2000 W/m2.
LP 471 ERY: Radiometric probe for TOTAL EFFECTIVE IRRADIANCE (Weff/m2) according to the UV action curve (CEI EN 60335-2-27) complete with SICRAM module. Spectral range: 250 nm…400 nm, quartz diffuser for cosine correction. Measurement range: 0.1Å10-3Weff /m2 … 2000 Weff /m2.
LP BL: Base with levelling device for the probes.