Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotrade.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

KYORITSU 6020/6030[22 Mar. 2009, 20:34:33]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalJepang

Keterangan

• Water resistant (IEC 60529 IP57)
• Test leads are stored in a cord reel module
• Easy-to-read large digital display
• The instrument automatically turns itself off in about 30 minutes to conserve battery life, if no push buttons are pressed.
• Illumination on test probes for work at night or in dimly lit locations
• Display back-light to improve legibility in poor lighting conditions
• Autoranging; three ranges for insulation resistance, two ranges for earth resistance and two AC voltage ranges
• The instrument and all accessories in one carrying case
• AC voltage range;
• True RMS sensing permits accurate measurement of voltage with distortion and harmonics generated by equipment using SCRs or TRIACs.

• Insulation resistance range;
• Three test voltages; Model 6020 (125V, 250V, 1000V)
• Three test voltages; Model 6030 (250V, 500V, 1000V)
• 1mA test current at the minimum load.
• Automatically releases electric charges stored in the circuit under test.
• Remaining charges can be observed on AC voltage range
• Remote control switch on a test probe

• Earth resistance range;
• Checks resistance of auxiliary earth bars
• Can make both simplified and normal measurement

• Phase test;
• LEDs indicate whether phase sequence is correct or reversed as well as open phase, if any.
• Rated voltage from 100V to 600V AC

Insulation Test Specifications :
- Test Voltage : 125V/250V (6020) 250V/500V (6030) 1000V (6020/30)
- Measuring Ranges
(M©) : 0 ~1.999M©
1.00 ~19.99M©
10.0 ~199.9M© 0 ~19.99M©
10.0 ~199.9M©
100 ~1999M© (6020/30)
(3 auto ranges)
- Accuracy : ±2%rdg ±3dgt, ±10%rdg (on 1000~2000M©)
- Open Circuit Voltage : +20% -0% of Rated Test Voltage
- Rated Test current : 1mA DC +20%-0%
Short Circuit current 1.3mA DC approx.
- Effect of AC Component
of Terminal Voltage : Within ±10% of reading when 5µF capacitor is connected in parallel on insulation test
- Overload Protection : 1200V (DC + ACp-p) for 10 seconds
Earth Resistance Test Specifications :
- Measuring Ranges(©) : 0 ~199.9©
100 ~1999© (2 auto ranges)
- Accuracy : ±2%rdg ±3dgt
(at 500© auxiliary earth resistance)
- Measuring Method : By constant current inverter 820Hz approx. 2mA approx.
- Overload Protection : 200V AC for 10 seconds between measuring terminals
Voltage Test Specifications :
- Measuring Ranges (V) : 0 ~ 199.9/100 ~ 600V (2 auto ranges)
- Accuracy : ±1%rdg ±4dgt
Sensing True RMS
- Input Impedance : 2M©
- Overload Protection : 900V AC for 1 minute
Phase Check Specifications :
- Measuring Range : 100 ~ 600V (50Hz/60Hz)
(for checking correct or reverse phase and open phase)
General :
- Display : 3 1/2(1999)digit large LCD
- Response Time : Approx. 4 seconds for AC voltage and earth resistance tests
Approx. 5 seconds for insulation resistance tests.
- Withstand Voltage : 5550V AC for one minute
- Effect of Drop : No electrical and mechanical damage shall occur when the unit
is dropped from a height of 1 m onto the concrete floor.
- Effect of Temperature : Readings shall not differ greater than specified below when taken at a reference temperature of 23ºC and varied temperature of 0ºC and 40ºC. AC Voltage 3% ±2 dgt insulation resistance and earth resistance 5% ±2 dgt
- Operating Temperature Range : 0-40ºC
- Dimensions : 130 × 238 × 207mm
(main body plus cord reel module)
105 × 238 × 207mm (main body only)
- Weight : Approx. 1.6kg (main body only)
Approx. 750g (cord reel module only)
- Power Supply : 1.5V LR6 alkaline battery or equivalent × 8 (for main body only)
1.5V LR6 alkaline battery or equivalent × 1 (probe only)
- Safety Standard : IEC 61010-1 CAT.III 600V Pollution Degree 2
- Accessories : 7092 (Cord Real)
8082 (Extension Probe)
7089 (Test Lead (large))
7090 (Test Lead (small))
7088 (Test Lead for Phase Check)
7091 (Test Lead) x 1set(red-20m, yellow-10m, green-5m)
8083 (Auxiliary Earth Spikes) x 1set
9081 (Carrying Case)
LR6 x 9, Instruction Manual,
Shoulder strap, Shoulder Pad, Set of "0" rings
- Optional : 2417 (Water Proof Leakage Clamp Meter)
7093 (Cord for Extension Probe)
9080 (Aluminum Carrying Case)

* A full set (deluxe version complete with aluminum carrying case and leakage clamp meter) is available as Model 6020T or 6030T.