Selamat Datang di Indotrade.com
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade Tahun ke-15
ALAT LABORATORIUM, www.peralatanlaboratorium.com PT. ASKOTAMA INTI NUSANTARA 021-84307982 Alat lab, Alat Labor, Alat Laboratori, Peralatan Laboratorium, Jual Alat Laboratorium, Distributor Alat Laboratorium, Supplier Alat Laboratorium, Alat Laboratorium M
http://indotrade.com/askotama/
Informasi Kontak
E-mail:
Situs Web:
Nomor Telpon:
Nomor telpon Tn. Ir. di Bekasi
Nomor Ponsel:
Nomor ponsel Tn. Ir. di Bekasi
Nomor Faks:
Nomor faks Tn. Ir. di Bekasi
Alamat:
KOMPLEK BUMI DIRGANTARA PERMAI, Jl. Hercules Blok J1 No. 10 Jatisari
Bekasi 17426, Jawa Barat
Indonesia
Alat Laboratorium www.askotamalaboratorium.com Peralatan Laboratorium, Alat Lab, Alat Labor, Alat Laboratori, Distributor Alat Laboratorium, Supplier Alat Laboratorium
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Katalog Produk

AAS WFX-120B[7 Feb. 2011, 0:05:22]
HargaAgent Price
Jumlah Pesanan:
Cara PembayaranTunai
Kemas & PengirimanUnit
Negara AsalChina

Keterangan

WFX- 120B Flame Atomic Absorption Spectrophotometer ( AAS )

Manufacturer : RAYLEIGH
ISO 9001: 2000 & ISO 4001: 2004

Features

1 Innovated rich oxygen air-acetylene flame analysis technique( WFX-110B) :

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950 which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It' s break-through in flame AAS analysis

2 Flame atomization system with flame emission burner

2.1 A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc.( WFX-110B/ 120B)

3 Accurate fully automated control system

3.1 Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

3.2 Automatic wavelength scanning and peak picking

3.3 Automatic spectral bandwidth changing

3.4 Automatic ignition

4 Perfect safety protection measures

4.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

5 Advance and reliable electronic design

5.1 Adopting large-scale programmable logic array and Inter I2C bus technology

5.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

6 Easy and practical analysis software

6.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization

6.2 Automatic sample dilution, automatic calculation and analytical result automatic print out

Main Specification
Wavelength range
190-900nm
Wavelength accuracy ± 0.25nm
Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% .
Baseline stability 0.004A/ 30min
Background correction The D2 lamp background correction capability at 1A is better than 30 times
The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110B/ 120B)

Light Source System Lamp turret 6-lamp turret ( WFX-120B) ; Auto-alignment, fully automated scan and peak-picking.
Lamp current adjustment 400Hz square wave pulse

Wide pulse current: 0~ 25mA,
Narrow pulse current: 0~ 10mA

Lamp power supply mode 400Hz square wave pulse;

100Hz narrow square wave pulse+ 400Hz wide square wave pulse ( WFX-110B/ 120B)

Optical System Monochomator Single beam, Czerny-Turner design grating monochromator
Grating 1800 l/ mm
Focal length 277mm
Blazed Wavelength 250nm
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
Flame Atomizer Burner 10cm single slot all-titanium burner
Spray chamber Corrosion resistant all-plastic spray chamber
Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7ml/ min
Emission burner Provided with WFX-120B
Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.
Software Windows operating system
Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat times Maximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation.
Multi-task Functions Sequential measurement for multi-element determination in one sample
Condition reading With model function
Result printing Measurement data and final analytical report printout, editing with Excel
Standard RS-232 serial port communication
Characteristic Concentration and Detection Limit Normal Air-C2H2 flame

Oxygen-rich Air-C2H2 flame
Cu: Characteristic concentrationd0.025mg/ L, Detection limitd0.006mg/ L;
Ba: Characteristic concentration d 0.22mg/ L
Al: Characteristic concentration d 0.4mg/ L
Function Expansion Hydride vapor generator can be connected for hydride analysis
Dimensions and weight Main unit 102× 49× 54cm, unpacked 80kg

Warranty : 12 months, full services