Selamat Datang di Indotrade.com
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade Tahun ke-14
ANDALAN INSTRUMENT GROUPANDALAN INSTRUMENT GROUP
http://indotrade.com/aps_weatherstation/
\"JENCO INSTRUMENT - JEKEN Ultrasonic Cleaner - E_INSTRUMENT - ASSEMBLAD Gas Analyzer - KOEHLER - MITECH Ultrasonic thickness - DAVIS Weather Station - EUTECH - SOCOREX Liquid Handling - MEMMERT - BLUE GIZMO - HACH - OHAUS Balance - VITLAB - DURAN - KETT
Informasi Kontak
Nama:

Tn. Edy Girsang/ maria [Pemasaran]

E-mail:
Situs Web:

Pesan Instan:

Windows Live: http://indonetwork.co.id/46NDMyOTQ4OjE-kxmx-zMTQwMDI4NTI.html?op=sms http://indonetwork.co.id/46NDMyOTQ4OjE-kxmx-zMTQwMDI4NTI.html?op=sms
Y!: edy_girsangta 
Nomor Telpon:

Nomor telpon Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Ponsel:

Nomor ponsel Tn. Edy Girsang/ maria di BEKASI UTARA

Nomor Faks:

Nomor faks Tn. Edy Girsang/ maria di BEKASI UTARA

Alamat:

Jl. Muchtar Tabrani , Bintang Metropol Blok A7 No16
BEKASI UTARA 17122, Jawa Barat
Indonesia

Alamat Tervalidasi

www.andalaninstrument.com
Rata-rata Tinjauan Pemakai
Tidak ada ulasan untuk perusahaan ini Menulis tinjauan

Unduhan (10)
Brosur Met One Auto....brosur Met One Data....Brosur Gray wolf multy....Brosur Chiyoda Pipet....3gtrack GPRS Data....3gtrack GPRS Modem3gtrack GPS Tracker GS....AIRMAR Ultar Sonic....Lihat semuanya

Jual

E-INSTRUMENTS, Temperature Calibrators: HC-DB35
Hargainquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Jumlah1 unit
Kemas & Pengirimanper unit
Negara AsalAmerika Serikat
Dual Dry Block Calibrator — Hot & Cold

Dual Dry Block to Calibrate 2 Temperature Sensors simultaneously and/ or at 2 different Temperature in quick time
Most Cost Effective Model in Market to Calibrate over wide range:
-35° C from amb. to 350° C
Truly Portable and Ideal for Field or Lab use
Fast Heating and Cooling times
Cold Bath: -35° C from amb. to 123° C
Hot Bath: 50° C to 350° C ( to 660° F)
Accuracy
Cold Bath: ± 0.05° C Hot Bath: 0.1% F.S.
Stability
Cold Bath: ± 0.5° C Hot Bath: ± 0.5° C
Resolution
Cold Bath: 0.1° C Hot Bath: 1° C
Heating Time ( to Max.)
Cold Bath: 10 minutes ( approx.)
Hot Bath: 18 minutes ( approx.)
Cooling Time
Cold Bath: 20 minutes Hot Bath: 60 minutes
Well Diameter
Cold Bath: 19mm Hot Bath: 25mm
Well Depth
Cold Bath: 100mm Hot Bath: 120mm
Switch Test Facility / Supply Provided / 5 VDC ( open)
Housed in an elegant and study Pelican case