Selamat Datang di
A LABERMAN PT ( 021-586 3633)

Anggota Gratis
A LABERMAN PT ( 021-586 3633)
Indonesia
  • Jual

    Sell outdoor emergency light nfpa nema 4x / Lampu Emergensisingapore

    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Cara Pembayaran:
    Transfer Bank (T/T)
    Telp : 021-583 3633
    Fax : 021-584 4911
    Email: laberman@ cbn.net.id

    General Description
    The Max-Lite Series is ideal for locations where
    oil, water, and dust resistant equipment are required.
    The Max-Lite Series is UL listed for use in damp
    and wet locations with temperatures ranging from
    32° F ( 0° C) to 104° F ( 40° C) . Practical installations
    where the Max-Lite Series excels consist of
    manufacturing facilities, parking decks, warehouses,
    water treatment facilities and the like.
    Equipped with Intelli-Charge, the Max-Lite Series
    is provided standard with an on-board IR receiver
    and is pre-programmed for use with our optional
    hand held test device allowing for remote testing in
    accordance with all applicable building code
    requirements. One-minute and 90-minute testing
    may also be initiated via the push to test switch on
    the unit.
    The Intelli-Charge circuit is a continuous,
    real-time diagnostics circuit allowing for precise
    equipment readiness indications via the dual
    colored LED indicator. This indicator feature also
    serves as the AC power, charge status and mode of
    operation indicator for immediate recognition of the
    equipment operating state. The standard diagnostics
    function is enabled without the optional self-testing
    in order to provide the highest level of equipment
    readiness and for use in areas where unscheduled
    transfer testing is not desired. Microprocessor
    controlled temperature compensation is equivalent
    to 3mV/ C° , optimizing the useful life and readiness
    of the battery. The Max-Lite Series meets the Buy
    American requirements.
    Dimensions
    Max-Lite Series
    Hostile Environment Emergency Lighting
    6 and 12 Volt, 25 to 150 Watts
    Standard Self-Diagnostics Electronics*
    Housing
    Constructed of impact resistant, fiberglass reinforced
    polyester, the housing color is gray and includes
    stainless steel hardware. The view-through window
    allows easy monitoring of the optional voltmeter and
    ammeter. Available with NEMA rated polycarbonate
    sealed beam Par 36 tungsten or halogen lamp heads.
    Optional shatter-resistant shield for lamp heads is
    designed for use in food service areas.
    Intelli-Charge Diagnostic
    Electronics ( standard)
    120/ 277 VAC dual voltage input with surge protection
    is standard on all models. Charging system is
    microprocessor driven with software embedded
    diagnostic routine and precision temperature
    compensation. See specification sheet C1059 for
    technical specifications for the electronics. Surge
    protection, brownout, AC lockout, and low voltage
    disconnect features are standard.
    Intelli-Charge
    Self-Testing Diagnostics
    ( optional)
    The Intelli-Charge diagnostic/ charging platform with
    self-testing mode automatically runs a one-minute
    self-test every 30 days and a 30-minute test on the sixth
    and twelfth month. A one-minute or 90-minute test may
    be initiated via the push to test switch on the unit or by
    activating the appropriate test command on the optional
    IR test device.
    Warranty
    Three year full electronics warranty. One year full plus
    four year prorated lead calcium battery warranty. Five
    year full plus five year prorated nickel cadmium battery
    warranty.
    Battery
    Maintenance free, sealed lead calcium battery has an
    estimated service life of 5 years and an operating
    temperature range of 32° F ( 0° C) to 104° F ( 40° C) .
    Maintenance free, sealed nickel cadmium battery has
    an estimated service life of 10 years and an operating
    temperature range of 32° F ( 0° C) to 104° F ( 40° C) .
    Batteries supply 90 minutes of emergency power.
    Code Compliance
    UL 924 listed
    UL damp and wet location listed 32° F ( 0° C) to
    104° F ( 40° C)
    NFPA 70 and NFPA 101, NEC, BOCA, OSHA and
    IBC illumination standards
    NSF Standard 2 â Splash Zoneâ
    Electrical Specifications
    Input power requirements
    6 Volt
    25-50W - 0.157A ( 120VAC) , 0.069A ( 277 VAC)
    75W - 0.222A ( 120VAC) , 0.094A ( 277 VAC)
    12 Volt
    50-100W - 0.289A ( 120VAC) , 0.135A ( 277 VAC)
    125W - 0.433A ( 120VAC) , 0.188A ( 277 VAC)
    150W - 0.470A ( 120VAC) , 0.203A ( 277 VAC)
    TYPE:
    CATALOG NO.:
    Shown: MN25ZV2IC
    Ordering Information ( Example: MN25ZV2IC)
    FACTORY INSTALLED
    OPTIONS2
    A = Ammeter
    BD = Battery Disconnect Switch
    EX = Special Input Transformer ( specify voltage & frequency)
    F1 = 120 VAC Fuse
    F2 = 277 VAC Fuse
    P1 = 120 VAC Power Switch
    P2 = 277 VAC Power Switch
    S = Shatterproof Lexan Lamp Head Lens
    T = Self-Testing Diagnostics
    TA = Audible Self-Testing Diagnostics
    TD = Time Delay ( 15 minutes)
    V = Voltmeter
    NOTES:
    1) For self-testing models refer to options. 2) Some option combinations may impact UL listing. Consult factory for specifications.
    ACCESSORIES
    ( order as a separate line item)
    ICIR = Intelli-Charge Infra-Red Remote
    WG = Wire Guard
    Dimensions are approximate and subject to change.
    SERIES/ BATTERY LAMP HEADS # OF HEADS
    Blank = No Lamp Heads
    1 = One Lamp Head
    2 = Two Lamp Heads
    3 = Three Lamp Heads
    Chloride Systems is a Philips group brand
    IC
    MODEL
    DESIGNATOR1
    IC = Intelli-Charge
    Diagnostic
    Electronics
    6 Volt, Tungsten
    ZM = 8 Watts
    ZN = 18 Watts
    ZO = 25 Watts
    6 Volt, Halogen
    ZU = 8 Watts
    ZV = 12 Watts
    12 Volt, Tungsten
    ZQ = 12 Watts
    ZR = 18 Watts
    ZS = 25 Watts
    12 Volt, Halogen
    ZW = 8 Watts
    ZX = 12 Watts
    Z5 = 50 Watts
    Z5F = 50 Watts,
    Flood
    6 Volt, Lead Calcium
    MC25 = 25 Watt Unit
    MC50 = 50 Watt Unit
    MC75 = 75 Watt Unit
    6 Volt, Nickel Cadmium
    MN25 = 25 Watt Unit
    MN50 = 50 Watt Unit
    MN75 = 75 Watt Unit
    12 Volt, Lead Calcium
    MTC50 = 50 Watt Unit
    MTC75 = 75 Watt Unit
    MTC100 = 100 Watt Unit
    MTC125 = 125 Watt Unit
    MTC150 = 150 Watt Unit
    12 Volt, Nickel Cadmium
    MTN50 = 50 Watt Unit
    MTN75 = 75 Watt Unit
    MTN100 = 100 Watt Unit
    MTN125 = 125 Watt Unit
    MTN150 = 150 Watt Unit
    * Self-powered models incorporate the Intelli-Charge diagnostics
    electronics package. Self-testing is a factory installed option.
    15.2â
    ( 38.6 cm)
    13.2â
    ( 33.5 cm)
    21.4â
    ( 54.4 cm)
    7.1â
    ( 18.0 cm) Specification Data for Max-Lite Series Hostile Environment Emergency Lighting Units
    Suggested Specification
    Furnish and install Chloride Systemsâ Max-Lite Series emergency lighting unit model ___________________. The unit shall be listed to Underwriter' s Laboratories,
    Inc. standard 924 and meet all applicable standards in the National Electrical Code ( NEC) , International Building Code ( IBC) as well as all state and municipal
    requirements. The unit shall be UL wet location listed standard for use in areas with temperatures ranging from 32º F ( 0º C) to 104º F ( 40º C) . Additional listings shall
    include NSF standard 2 " Splash Zone" .
    INSTALLATION AND OPERATION - The unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, unswitched power source. Installation must comply with the
    NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically to battery power and maintain the required illumination level
    for a minimum period of not less than 90-minutes at the coldest rated temperature of the unit without the need to de-rate the capacity of the equipment. Upon
    restoration of utility power, the charging system shall restore the battery to full charge within UL 924 requirements following a complete discharge cycle of the unit.
    ELECTRONICS - The equipment shall be provided with Chloride' s Intelli-Charge electronics system. Intelli-Charge will detect and notify the installer of incorrect wiring
    of the transformer primary and restrict any damaging effects from reaching the printed circuit board. The Intelli-Charge electronics shall provide continuous, real-time
    monitoring of all the critical equipment functions including, but not limited to: line voltage status and condition, charger fault, transfer fault, battery fault, and load loss
    detection to 10% of all connected loads. A visual indicator provides fault notification with the option to add an audible alarm as well. The optional self-testing software
    shall satisfy the periodic testing requirements in NFPA 101, Life Safety Code as well as the International Fire Code ( IFC) . The Intelli-Charge with self-testing option
    automatically runs a one-minute test every 30 days and a thirty minute test on the sixth and twelfth month. The Intelli-Charge system shall employ temperature
    compensation which continuously samples the ambient temperature and adjusts the charging system for typical and dramatic temperature fluctuations at a rate equal to
    3mV/ Cº to maximize the life and readiness of the batteries. An on-board IR receiver shall be standard and pre-programmed to operate from an optional hand-held IR
    test device ( available as an accessory item) .
    BATTERY - The battery shall be either maintenance-free sealed lead calcium or nickel cadmium type. The nickel cadmium battery shall utilize sintered plate
    construction and polypropylene separators for trouble-free operation in ambient temperatures up to 104º F ( 40º C) and be tested and approved under IEC standard
    61951-1. The lead calcium battery shall provide trouble-free operation in temperatures up to 104º F ( 40º C) .
    HOUSING - The housing shall be constructed of impact-resistant, fiberglass reinforced polyester. Internal or external mounting feet shall be provided standard. The unit
    shall be UL wet location listed.
    C1007R22
    12/ 10 IH
    272 West Stag Park Service Road ⢠Burgaw NC 28425
    Telephone: ( 910) 259 1000 ⢠Facsimile: ( 800) 258 8803
    www.chloridesys.com
    * The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/ 50/ 20. Chloride is not responsible for site specific conditions that may alter the results.
    Average initial footcandles at floor = 1.12
    Maximum initial footcandles at floor = 4.9
    Minimum initial footcandles at floor = 0.2
    Maximum to minimum ratio = 24.50
    Optics* ( IES formatted files are available on-line)
    Wall Mounted 7.5' AFF, 12V 12W Halogen Lamp Heads Represented
    2.
    8.
    2.2
    2.7
    9.
    1.0
    2.3
    2.7
    8.
    2.
    2.
    8.
    2.8
    2.2
    9.
    9.
    2.4
    2.6
    7 .
    2.
    3.
    1.3
    2.1
    3.1
    8.
    8.
    1.9
    3.3
    1.3
    3.
    3.
    1.3
    3.1
    2.0
    8.
    7.
    1.9
    3.2
    1.3
    2.
    2.
    4.
    5.
    6.
    5.
    5.
    5.
    6.
    5.
    2.
    2.
    4.
    6.
    5.
    5.
    5.
    5.
    6.
    4.
    .2 9 ft.
    7.5 ft.
    30 ft.
    1 FC Average
    Average initial footcandles at floor = 2.97
    Maximum initial footcandles at floor = 6.6
    Minimum initial footcandles at floor = 1.0


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.com. Hak Cipta Dilindungi Undang-undang.