Selamat Datang di
A LABERMAN PT ( 021-586 3633)

Anggota Gratis
A LABERMAN PT ( 021-586 3633)
Indonesia
  • Jual

    outdoor emergency lighting/ lampu emergency nema 4x / Lampu Emergensi indonesia

    outdoor emergency lighting/ lampu emergency nema 4x / Lampu Emergensi indonesia

    Jumlah Pesanan:
    Negara Asal:
    Amerika Serikat
    Telp : 021- 586 3633
    Fax : 021- 584 4911
    Email: laberman@ cbn.net.id

    General Description
    The Rhyno is a state of the art industrial emergency
    lighting product for extreme environments. The Rhyno
    is designed to be protected against liquid, moisture,
    dirt, and dust entry. The Rhyno is approved for NEMA
    4X and IP66 areas, and is additionally UL listed for
    wet locations, cold ambient conditions, high ambient
    conditions, and extreme ambient conditions. The
    Rhyno Series meets the Buy American requirements.
    Illumination
    Illumination is accomplished with two lamp heads
    internally mounted on the bottom of the unit for
    optimum path of egress illumination. Lamps are held
    in a molded swivel assembly and are fully adjustable.
    Each lamp head utilizes a PAR 36 sealed beam
    tungsten or halogen lamp.
    Installation
    The Rhyno is supplied standard with a wall mount
    bracket. A universal mounting kit for column, pole, or
    I-beam mounting is available as an accessory item.
    Dimensions
    Rhyno Series
    NEMA 4X, IP66, Harsh Environment Emergency Lighting
    Standard Self-Diagnostics Electronics*
    6, 12, and 24 Volt, 25 to 150 Watts* *
    Housing
    Constructed of impact-resistant Lexan® with corrosion
    resistant hardware. Housing color is gray.
    A one-piece, molded gasket, and unexposed metallic
    hardware prolong product life in highly corrosive areas.
    A hinged, removable cover allows for hands-free wiring.
    Housing is rated for use in NEMA 4X and IP66 areas
    and is additionally UL wet location listed.
    Intelli-Charge Electronics
    120/ 277 VAC dual voltage input with surge protection
    is standard on all models.
    Charging system is microprocessor driven with
    software embedded diagnostic routine and precision
    temperature compensation. See specification sheet
    C1059 for technical specifications for the electronics.
    Surge protection, brownout, AC lockout, and low
    voltage disconnect features are standard.
    Battery
    The Rhyno battery assemblies have been pre-qualified
    for use based on anticipated ambient temperatures.
    Battery chemistries consist of sealed, maintenance-free
    lead calcium, pure lead, and nickel cadmium.
    Batteries supply a minimum of 90 minutes of
    emergency power at the lowest rated temperature of the
    model selected without de-rating the fixture.
    Intelli-Charge
    Self-Testing Diagnostics
    ( optional)
    The Intelli-Charge diagnostic/ charging platform with
    self-testing mode automatically runs a one-minute
    self-test every 30 days and a 30-minute test on the
    sixth and twelfth month. A one-minute or 90-minute
    test may be initiated via the push to test switch on the
    unit or by activating the appropriate test command on
    the optional IR test device.
    Warranty
    Three year full electronics warranty
    One year full plus four year prorated lead calcium or
    pure lead battery warranty
    Five year full plus five year prorated nickel cadmium
    battery warranty
    Electrical Specifications
    Input Power Requirements
    6 Volt and 12 Volt, Standard and â Hâ - High Ambient
    Units
    120 VAC, 60 Hz = 0.319 A, 277 VAC, 60 Hz = 0.142 A
    6 Volt and 12 Volt, â Câ - Cold Ambient and
    â Eâ - Extreme Ambient Units
    120 VAC, 60 Hz = 0.683 A, 277 VAC, 60 Hz = 0.305 A
    24 Volt Models
    120 VAC, 60 Hz = 0.507 A, 277 VAC, 60 Hz = 0.227 A
    Code Compliance
    UL 924 listed
    UL wet location listed
    NSF Standard 2 â Splash Zoneâ
    NEMA 250 ( NEMA 4X classification)
    NFPA 101, NEC, BOCA, OSHA and IBC illumination
    standards
    IEC 61951-1 Life Testing ( NiCad batteries)
    IEC 529 ( 60529) IP66
    Model number RN215PF2IC ( with available factory
    options) is UL 924 listed for 8-hour run time in the
    emergency mode
    TYPE:
    CATALOG NO.:
    Shown: RN65PA2IC
    Ordering Information ( Example: RN65PA2IC)
    RN
    SERIES
    RN = Rhyno
    Series
    Industrial
    Emergency
    Lighting
    Fixture
    BATTERY
    VOLTAGE
    6 = 6 Volts DC
    2 = 12 Volts DC
    4 = 24 Volts DC1
    CAPACITY
    2 = 25 Watts
    5 = 50 Watts
    7 = 75 Watts
    1 = 100 Watts
    1
    12 = 125 Watts
    3
    15 = 150 Watts
    3
    LAMP
    DESIGNATOR
    OPTIONS
    A = Ammeter
    ACF1 = 120 Volt AC Input Fuse
    ACF2 = 277 Volt AC Input Fuse
    ACP1 = 120 Volt AC Disconnect
    Switch
    ACP2 = 277 Volt AC Disconnect
    Switch
    BDS = Battery Disconnect Switch
    EX = Special Input Transformer
    2
    ( specify voltage & frequency)
    T = Self-Testing Diagnostics
    ( non-audible)
    TA = Audible Self-Testing
    Diagnostics
    TD = Time Delay
    V = Voltmeter
    LAMP HEAD
    QUANTITY
    0 = No Heads
    2 = Two Heads
    16.0â
    ( 40.64 cm)
    17.4â
    ( 44.2 cm)
    9.0â
    ( 22.86 cm)
    9.3â
    ( 23.62 cm)
    IC
    MODEL
    DESIGNATOR
    IC = Intelli-Charge
    Self-Diagnostic
    Electronics
    Note:
    1) 24 volt systems only available in 100 watt configurations.
    2) Certain option combinations may impact UL listing, consult factory.
    3) 125 and 150 watt units available in 12VDC configurations only.
    ACCESSORIES
    ( order as a separate line item)
    NUMK = Universal Mounting Kit
    ( column, pole, I-beam)
    ICIR = Intelli-Charge Infra-Red Remote
    ENVIRONMENT* * *
    See Capacity & Environment
    for Limited Availability* * *
    Blank = Wet Location
    Listed ( 0° C to 40° C)
    C = Cold Ambient
    Conditions, Wet
    Location Listed
    ( -40° C to 40° C)
    H = High Ambient
    Conditions, Wet
    Location Listed
    ( 0° C to 55° C)
    E = Extreme Ambient
    Conditions, Wet
    Location Listed
    ( -40° C to 55° C)
    6 Volt, PAR 36
    Sealed Beam
    Tungsten
    PA = 8 Watt
    PB = 18 Watt
    PC = 25 Watt
    PD = 30 Watt
    6 Volt, PAR 36
    Sealed Beam
    Halogen
    PI = 8 Watt
    PJ = 12 Watt
    PP = 20 Watt
    12 Volt, PAR 36
    Sealed Beam
    Tungsten
    PE = 12 Watt
    PF = 18 Watt
    PG = 25 Watt
    PH = 30 Watt
    12 Volt, PAR 36
    Sealed Beam
    Halogen
    PK = 8 Watt
    PL = 12 Watt
    PM = 37 Watt
    PN = 50 Watt
    24 Volt, Sealed
    Beam
    Tungsten
    PO = 50 Watt
    * All models incorporate the Intelli-Charge diagnostics
    electronics package. Self-testing is a factory installed option.
    * * 24 volt system available in 100 watt capacity only
    * * * CAPACITY & ENVIRONMENT
    SELECTION
    C = 12V, 100W; 12V, 125W; 12V, 150W
    H = 6V, 50W; 12V, 50W; 12V, 100W; 12V, 125W; 12V, 150W
    E = 6V, 50W; 12V, 50W; 12V, 100W; 12V, 125W; 12V, 150W
    All other configurations are standard
    wet location listed from 0° C to 40° C.
    See reverse for more dimensions.
    NEMA
    4X
    IP66
    Chloride Systems is a Philips group brandHousing
    Constructed of impact-resistant Lexan® . Housing
    color is gray. Housing is rated for use in NEMA 4X
    and IP66 areas and is additionally UL wet location
    listed.
    Includes one-piece, molded formed-in-place gasket
    and unexposed metallic hardware.
    Hands-free wiring is possible with a hinged,
    removable cover.
    Illumination
    The Rhyno Series is available with or without lamp
    heads installed on the fixture. Available lamp heads
    include Par 36 sealed beam tungsten or halogen
    lamps in a fully adjustable swivel assembly.
    Full IES file data support is available on-line at
    www.chloridesys.com.
    Electronics
    Intelli-Charge Standard Features
    All operational features of the Rhyno Series are
    controlled by an 8-bit microprocessor to provide
    unmatched reliability and performance.
    Microprocessor standard features include:
    Transformer isolated input
    Low-voltage disconnect ( LVD)
    AC lockout ( line latch)
    AC power indicator
    Brownout protection
    Charge status indicator
    Visual fault indicator
    Audible user interface control
    On-board IR receiver
    Precision temperature compensation
    For detailed specifications regarding the Intelli-Charge
    for unit equipment, see specification sheet C1059.
    Dual voltage 120/ 277 VAC, 60 Hz input with surge
    protection is standard on all models.
    The low voltage disconnect ( LVD) feature will
    disconnect the battery prior to an unacceptable deep
    discharge, but not before the required 90 minute
    emergency operation.
    The brownout protection circuitry will automatically
    switch the unit into the emergency mode if the utility
    voltage drops below 25% of nominal input voltage.
    The AC lockout ( line latch) feature prevents battery
    drain prior to the initial energizing of utility power,
    and allows the installer to complete all wiring and
    electrical connections without energizing the
    emergency circuit.
    Battery
    Maintenance-free, sealed nickel cadmium, lead
    calcium and pure lead batteries are pre-qualified
    based on anticipated ambient temperature exposure.
    All capacity ratings are based on the lowest extreme
    temperature rating of the fixture, producing a
    minimum of 90 minutes emergency operation without
    de-rating the unit.
    Specification Data for Rhyno
    Suggested Specification
    Furnish and install Chlorideâ s Rhyno emergency lighting unit model _____________________. The unit shall meet Underwriterâ s Laboratories, Inc. Standard # 924
    and the National Electrical Code ( NEC) . The unit shall be third party tested and approved for use in NEMA 4X areas in accordance with the requirements of NEMA 250,
    third party tested and approved for IP66 areas, third party tested and approved for NSF Standard 2 â Splash Zoneâ , and be additionally UL wet location listed.
    INSTALLATION AND OPERATION - Unit shall be easily field connected to a 120 or 277 VAC, 60 Hz, unswitched power source. Installation must comply with the NEC
    as well as other applicable codes. ( Emergency Operation Only) - Upon utility power failure or brownout, the unit shall automatically transfer to battery power and maintain
    the required illumination level for a minimum period not less than 90 minutes at the coldest rated temperature of the unit. Upon restoration of utility power, the charger
    shall restore the battery to full charge within UL 924 requirements following a rated discharge of not less than 90 minutes.
    ELECTRONICS - All models shall be provided with Chlorideâ s Intelli-Charge self-diagnostics electronics platform. Intelli-Charge will detect and notify the installer
    regarding incorrect wiring of the transformer primary and restrict the damaging effects from affecting the printed circuit board. The Intelli-Charge electronics package shall
    provide continuous, real-time monitoring of all the critical equipment functions including, but not limited to: line voltage status and condition, charger fault, transfer fault,
    battery fault, and lamp load fault and notify personnel with a visual indicator sequence. Optional audible diagnostics shall be available from the factory. The optional
    self-testing software shall satisfy the periodic testing requirements in NFPA 101, Life Safety Code as well as the International Building Code ( IBC) . The Intelli-Charge
    diagnostic/ charging platform with self-testing mode automatically runs a one-minute self-test every 30 days and a 30-minute test on the sixth and twelfth month. The
    Intelli-Charge circuit shall continuously sample ambient temperature conditions and adjust the charging regime to compensate for typical and dramatic ambient conditions
    equal to 3mv/ º C compensation to maximize the life of the battery. An on-board IR receiver shall be standard and pre-programmed to operate from an optional IR user
    interface device ( available as an accessory item) .
    BATTERY - The battery shall be either a maintenance-free, sealed nickel cadmium, lead calcium, or pure lead battery. The Rhyno Series battery shall be pre-qualified
    based on anticipated ambient temperature conditions. The nickel cadmium battery shall utilize sintered plate construction and polypropylene separators for trouble-free
    operation in ambient temperatures up to 131° F ( 55° C) and be tested in accordance with IEC Standard 61951-1. The pure lead battery shall provide trouble-free operation
    in temperatures up to 131° F ( 55° C) . The lead calcium battery shall provide trouble-free operation in temperatures up to 104° F ( 40° C) . Nickel cadmium batteries shall be
    supplied with a five year full warranty. Lead calcium and pure batteries shall be supplied with a one year full warranty.
    HOUSING - The unit housing shall be constructed of impact-resistant Lexan® . The housing color shall be gray.
    C1060R9
    10/ 10 IH
    272 West Stag Park Service Road ⢠Burgaw NC 28425
    Telephone: ( 910) 259 1000 ⢠Facsimile: ( 800) 258 8803
    www.chloridesys.com
    Conduit Entry Point Knockouts
    7/ 8â
    Top View
    Right
    Side
    Left
    Side
    11.9â
    ( 30.23 cm)
    8.7â
    ( 22.1 cm)
    3.3â
    ( 8.38 cm)
    Backplate
    Top
    View
    Front
    View
    Dimensions are approximate and subject to change.
    Intelli-Charge
    System Reset: Two pres System Reset: Two presses of " SILENCE ALARM" ses of " SILENCE ALARM"
    button followed by tw button followed by two presses of " CANCEL" o presses of " CANCEL"
    but button. ton.
    Interpretation of Flash Interpretation of Flashing Indicator lights on ing Indicator lights on
    Equip Equipment: ment:
    Green LED Green LED Indicator: Indicator:
    ⢠Steady O Steady On - Normal n - Normal
    ⢠Slow Flash - Ba Slow Flash - Battery Charging ttery Charging
    ⢠Fast Flash - Un Fast Flash - Unit is self-testing it is self-testing
    Red LED I Red LED Indicator: ndicator:
    ⢠Single Flash - Single Flash - Battery Fault Battery Fault
    ⢠Double Flash - Double Flash - Lamp Failure Lamp Failure
    ⢠Triple Flash - Triple Flash - Charger Fault Charger Fault
    ⢠Quad Flash - Emerg Quad Flash - Emergency Transfer Failure ency Transfer Failure
    Red and Green LED indi Red and Green LED indicators flashing together: cators flashing together:
    ⢠Slow Flashing - L Slow Flashing - Low Line Voltage ow Line Voltage
    ⢠Fast Flashing - Hi Fast Flashing - High Line Voltage gh Line Voltage
    Unit Equipment L Unit Equipment Lamp Calibration amp Calibration
    Press " Silence Alarm" twic Press " Silence Alarm" twice followed by one press e followed by one press
    of " Cancel" and one of " Cancel" and one press of " Silence Alarm" press of " Silence Alarm"
    For Service Cal For Service Call ( 910) 259-1000 l ( 910) 259-1000
    3.38â
    ( 8.58 cm)
    2.13â
    ( 5.41 cm)
    ICIR Front ICIR Back


Anda mendapat [3] permintaan baru.
Ke Menu Anggota

Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.com. Hak Cipta Dilindungi Undang-undang.