Portable Flue Gas Analyser A-500 Wohler
HargaNN
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & PengirimanUnit
Negara AsalJerman
Kenalkan ke teman Anda
Keterangan
Technical Data

O² -measurement

• Range : 0...21.0 Vol.-%

• Accuracy : 0.3 Vol.-% absolut

CO-measurement-solid fuel ( optional)

• Range : 0...4, 000 ppm

• Accuracy : ± 20 ppm: 0...400 ppm, ± 5% o.r.

NO-measurement ( optional)

• Range : 0...2, 000 ppm, continually resilient up to 1, 000 ppm
• Accuracy : 5 ppm: 0...100 ppm 5 % o.r.

NO2-measurement ( optional)

• Range : 0...500 ppm

• Accuracy : ± 5 ppm: 0...100 ppm, ± 5% o.r.

SO2-measurement ( optional)

• Range : 0...4, 000 ppm

• Accuracy : ± 10 ppm: 0...200 ppm, ± 5% o.r.

Ambient air temperature-TA

• Range : -20.0...99.9 ° C

• Accuracy : 1 ° C: 0...50 ° C

Flue Gas temperature measurement-TS

• Range : 0...800 ° C

• Accuracy : according to EN 50379

Draft and Differential Pressure-DP

• Range : 0...± 4, 000 Pa

• Accuracy : 3 Pa: 0...100 Pa, 3 % v.M.: 100...4, 000 Pa

CO2-Calculation

• Range : 0...CO2max

• Resolution : 0, 10%

Stack losses-QA

in reference to selected fuel

• Resolution : 0, 10%

Efficiency - ?

• Range : 0...100.0 % condensation is automatically detected
• Resolution : 0, 10%

Automatic CO purge pump dew point calculation:

in reference to the selected fuel,

• Resolution : 0.1 ° C

Condensate

• readings in kg/ m3 ( gas) or kg/ l ( oil)

Date / time

realtime clock with backup battery

• Storage temperature : -20...50 ° C

• Work temperature : 5...40 ° C

to meet specifications

Current supply

4 x AA rechargeable batteries or mains supply

• Weight : ca. 1, 300 g

• Size : 213 x 172 x 73 mm

Standard Unit A-500 :

• Sensor : O2, CO, NO, SO2

• Air temp. probe with 1.6 m cable

• Wö hler RP 72 soot pump set

• 25 pcs. Wadding

• 5 pcs. Coarse filter

• 3 pcs. Water stop filter

• Sluminium framed case

• Thermal fast printer