PT. SABERINDO PACIFIC - FIRE & SAFETY SPECIALIST
Anggota Gratis
PT Saberindo Pacific
Informasi Kontak
Nama:
Tn. Kusmin T [Pemasaran]
E-mail:
Situs Web:
Pesan Instan:

Y!: kusminardy 
Nomor Telpon:
Nomor telpon Tn. Kusmin T di Jakarta
Nomor Ponsel:
Nomor ponsel Tn. Kusmin T di Jakarta
Nomor Faks:
Nomor faks Tn. Kusmin T di Jakarta
Alamat:
Ruko Mega Grosir Cempaka Mas Blok J no.10 JL. Letjend Suprapto
Jakarta 10640, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

xxxx
Produk Terbaru
Bahasa :
CHEMGUARD Mobile Foam Cart
CHEMGUARD Mobile....
Harvik - Fireman Boot
Harvik - Fireman....

Katalog Produk

UNIPOS Combined fire detector FD3060
Jumlah Pesanan:
Kenalkan ke teman Anda
Keterangan
FD 3060 Combined fire detector – The fire detector provides reliable early warning of a Fire condition responding to fixed threshold smoke concentration or rate of rise of the temperature or fixed temperature threshold detected in the protected premises.

It combines the advantages of a type FD 3020 and a type FD3030 and it is an attractive option due to decreased expenses for supply and installation.

The detector complies with the requirements of the European Standard EN 54-5 ( temperature class A2R) and EN 54-7.

Technical data

Supply voltage

( 12-30) V DC

Duty mode current

150 ¼ A

Fire condition current

- with a base type 3000 & 3000D

( 8-25) mA

- with a base type 3000R & 3000DR

( 18-55) mA

Terminals

For wires with cross section ( 0.8-2.5) mm2

Operating temperatures

Minus 10oC to 55oC

Sensitivity

in accordance with EN54-5, class A2R and EN54-7

Mounting

Using bases of series 3000

Degree of detection

IP 40

Relative humidity

( 93± 3) % at 40oC

Dimensions ( base included)

Ø 106, h 55 mm

Casing material

ABS plastics, white

Weight

0.170

Protected area

Circle with diameter 10m, h 8m

3000 Standard Base – It is used upon operation with Fire Control Panels, where Fault Condition Removed detector shall be signaled as a Fault condition Interruption.

3000D Base with Schottky diode – It allows the Fire Control Panel to recognize Fault condition Removed detector from Faults condition Interruption.

3000R Base with relay output – It is used systems, where it is necessary that the activated fire detector activates additional device through the relay contact.

3000DR Base with Schottky Diode and Resistor – It is used in systems, where the activated fire detector must increase additionally the current in a line. It allows the Fire Control Panel to recognize Fault condition Removed detector from Fault condition Interruption.
Anda mendapat [3] permintaan baru.
Ke Menu Anggota
Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.com. Hak Cipta Dilindungi Undang-undang.