PT Saberindo Pacific
http://indotrade.com/pt_saberindo_pacific/
PT. SABERINDO PACIFIC - FIRE & SAFETY SPECIALIST
Depan
Info Perusahaan
Penawaran Dagang
Katalog Produk
Hubungi Kami
Kenalkan Kami
Anggota Gratis
Penawaran Jual (16)
Katalog Produk (159)
CHEMGUARD Mobile Foam....
Harvik - Fireman Boot
Q-Fire Helmet
Akron - Hose tester HT....
Akron - Portable By....
Akron - In Line....
Akron - GP Manual....
Akron - Ozzie Master....
Akron - Mercury Master
Akron - Mercury Quick....
Lihat semuanya
TOHATSU
Tohatsu Fire Pump type....
Tohatsu Fire Pump type....
Tohatsu Fire Pump type....
Tohatsu Fire Pump type....
Tohatsu Fire Pump type....
TOHATSU PORTABLE FIRE....
Q-FIRE FIRE....
Q-FIRE Dry Powder Fire....
Q-FIRE Halotron....
Q-FIRE Halotron Fire....
Q-FIRE CO2 Fire....
Q-FIRE Foam Fire....
Q-FIRE Water Fire....
Q-FIRE Fire Hose ( UK)
Q-FIRE Hosereels ( UK)
Fire Equipment
Flexline Fire Hose
Akron Nozzle & hydrant....
Kidde Fire Extinguisher
Q-Fire Helmet
Nomex III Fireman Suit
Harvik - Fireman Boot
Fire Gloves Model 7500
150/ 60 & 550/ 60....
2000 & 3000 Series Fire....
Comptrade high pressure....
Lihat semuanya
Safety Equipment
Comptrade high pressure....
Q-Fire Helmet
150/ 60 & 550/ 60....
2000 & 3000 Series Fire....
Fire Gloves Model 7500
Harvik - Fireman Boot
Nomex III Fireman Suit
Tyco/ Scott ACSfx
Tyco/ Scott ACSi
Sigma ASCmarine
Lihat semuanya
JOHSTADT Portable Fire....
JOHSTADT -TNP 10000
JOHSTADT -ANP 8000
JOHSTADT -ANP 6000
JOHSTADT -ANP 4000
JOHSTADT -ANP 3000
JOHSTADT -VF 2000 D
JOHSTADT -VF 1400 D
JOHSTADT -ZL 600 D
JOHSTADT -ZL 1000
JOHSTADT -EL 200
Lihat semuanya
UNIPOS Fire Detection & ....
UNIPOS Conventional....
UNIPOS Conventional....
UNIPOS Fire Control....
UNIPOS Fire Control....
UNIPOS Fire Control....
UNIPOS Smoke detector....
UNIPOS Rate of rise....
UNIPOS Manual Call....
UNIPOS Flame detector....
UNIPOS Fixed....
Lihat semuanya
Fire-Lite' s Alarm
Fire Lite' s....
Fire Lite' s....
Fire Lite' s Pull....
Fire Lite' s Pull....
Fire Lite' s....
Fire Lite' s....
Fire Lite' s....
Fire Lite' s....
Fire Lite' s....
Fire Lite' s Audio....
Lihat semuanya
Chemguard
CHEMGUARD Foam....
CHEMGUARD Foam....
CHEMGUARD Foam....
CHEMGUARD Foam....
CHEMGUARD Foam....
CHEMGUARD Foam....
CHEMGUARD BALANCED....
CHEMGUARD IN-LINE....
CHEMGUARD VERTICAL AND....
CHEMGUARD Foam Chamber
Lihat semuanya
JANUS
JANUS FM200 & CO2....
JANUS - FM-200 Fire....
JANUS LPCO2 - Fire....
JANUS HPCO2 - Fire....
Comptrade
Comptrade Portable Air....
Comptrade CTP - F 150/ ....
Comptrade Portable Air....
Tyco/ Scott
Tyco/ Scott ACSf
Tyco/ Scott ACSf ELSA
Tyco/ Scott ACSfx
Tyco/ Scott ACSi
Sigma ASCmarine
Akron
Akron - Assault
Akron - Mercury Quick....
Akron - DeckMaster
AKRON Turbojet Nozzle
Akron - Mercury Master
Akron - Apparatus Flow....
AKRON Trident HFRT-10
AKRON UltraHigh....
AKRON Saberjet Nozzle
Akron - Forestry....
Lihat semuanya
FIREXPRESS
Firexpress - 20 litre....
NIAGARA - Floating Pump
Niagara 1
Informasi Kontak
Nama:
Tn. Kusmin T [Pemasaran]
E-mail:
Situs Web:
www.saberindo.co.id
Pesan Instan:
Nomor Telpon:
Nomor Ponsel:
Nomor Faks:
Alamat:
Ruko Mega Grosir Cempaka Mas Blok J no.10 JL. Letjend Suprapto
Jakarta 10640, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai
Tidak ada ulasan untuk perusahaan ini
Menulis tinjauan
Produk Terbaru
Bahasa :
CHEMGUARD Mobile....
Harvik - Fireman....
Katalog Produk
Gambar lebih besar
UNIPOS Interactive Fire Control Panel IFS7002 One Signal Loop
Jumlah Pesanan:
Kenalkan ke teman Anda
Keterangan
Description:
Interactive Fire Control Panel IFS7002 – one signal loop - is designed to operate with addressable automatic fire detectors and manual call points. It controls addressable executive and input-output devices integrated into fire alarm loops. The addressable executive devices can be power supplied from the fire alarm loop and ext.supply or auxiliary user supply voltage of the Fire Control Panel. The panel has outputs provided for integration of external executive devices.
1. Technical data
1.1. Physical configuration
- 1 fire alarm loops
- 2 monitored outputs
- 1 relay outputs for fire condition
- 1 programmable relay outputs for fire condition
- 1 relay output for fault conditions
1.2. Fire alarm zones
- Maximum number of zones - 64
- Maximum number of fire detectors and in-out devices- 60
1.3. Fire alarm loops
- Maximum number of fire detectors in a loop - 125
- Connecting line - two-wire shielded
- Maximum resistance of a loop - 100W
- Output resistance of a loop - 20W
- Maximum consumption of a loop - 200mA
1.4. Monitored outputs - 2 pcs
- Type - potential
- lectrical characteristics - ( 24± 5) V/ 0, 5A
1.5. Relay output for fire conditions - 1 pc
- Type - potential free, switching,
- Electrical characteristics - 3A/ 125VAC; 3A/ 30VDC
1.6. Relay ( programmable) output for fire conditions - 1 pc
- Type - potential free, switching,
- Electrical characteristics - 3A/ 125VAC; 3A/ 30VDC
1.7. Relay output for fault conditions - 1 pc
- Type - potential free, switching
- Electrical characteristics - 3A/ 125VAC; 3A/ 30VDC
1.8. Performance
- Control over fire alarm loops and monitored outputs for fault conditions ( short circuit and interruption) and automatic reset
- Detection of removed devices in the loops and automatic reset
- Ability to set the zones in Coincidence Mode
- Two phases of Fire condition, programmable time for Fire condition stage I, separately for each zone
- Option to prolong the time period for Fire condition stage I with programmable inspection period, specified for each zone
- Built-in sounder for fire condition – one tonal, discontinuous, can be switched off
- Built-in sounder for fault condition – one tonal, discontinuous, can be switched off
- Built-in real time clock
- Set of test modes and options for adjustment:
¨ Setting the clock;
¨ Check ups on light and sound indications;
¨ Test of fire alarm zones;
¨ Adjustment of outputs and integrated external devices;
¨ Programming of parameters and modes of operation;
¨ Remote programming of the parameters from distant operator control point;
- Energy independent archive of registered events with the events type, date and hour – up to 1023 events;
- Interfaces for communication with external devices - CAN 2.0B and RS-232 ( directly or via modem) .
1.9. Indications of registered events
- Light indication - LED
- Text messages - LCD display,
320 E 240 points, backlit
- Sound signaling - built-in sounder
1.10. Power supply
1.10.1. Mains
- voltage - 220/ 230V
- frequency - 50Hz
1.10.2. Back up batteries
- battery type - lead, gel electrolyte
- number of batteries - 2 pcs
- connection - serial connection
- nominal voltage of the back up battery - 2x12V DC
- nominal capacity C20 - 5Ah
- charge voltage - 28V
1.10.3. Consumption on back up batteries supply
- at 24V -
menampilkan 134 dari 175 |
Sebelum : UNIPOS Interactive Fire....
|
Berikut : UNIPOS Interactive Fire....
Anda mendapat [
3
] permintaan baru
.
Ke Menu Anggota
© 2024
Indotrade.com
. Hak Cipta Dilindungi Undang-undang.