    Eutech PC 700

    The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
    : : Large screen in a compact footprint

    : : Meter accepts pH and Redox electrodes, in addition to Conductivity/ TDS – it’ s like having four meters in one!

    : : Up to 5-point push button calibration

    : : Selectable cell constant

    : : Auto-ranging across 5 Conductivity ranges

    : : Easy interchangeability of probes

    : : Non-volatile memory holds up to 100 data points

    : : Integral electrode holder

    Applications

    • Water quality testing • Checking metal finishes • Solutions • Cooling tower water • Printing fountain solutions • Boiler water • Brines • Drilling mud • Rinse tanks • Ponds • Pollution control • Recirculating systems • Waste water • Industrial process systems • General use in laboratories • Titration • Quality assurance • Ecological studies • Food-processing

    Specifications
    Product Specification Description
    pH
    Range -2.00 to 16.00 pH
    Resolution 0.01 pH
    Accuracy ± 0.01 pH
    Cal. Points Up to 5
    Buffer Sets USA ( 1.68, 4.01, 7.00, 10.01, 12.45) ,
    NIST ( 1.68, 4.01, 6.86, 9.18, 12.45)
    ORP
    Range ± 2000 mV
    Rel. mV Range ± 2000 mV
    Resolution 0.1 mV ( ± 199.9 mV) / 1 mV ( beyond)
    Accuracy ± 0.2 mV ( ± 199.9 mV) / ± 2 mV ( beyond)
    Conductivity
    Range 0.0 µ S to 200.0 mS
    Resolution 0.01 / 0.1 / 1 µ S ; 0.01 / 0.1 mS
    Accuracy ± 1 % full scale
    Cal. Points Automatic ( 84 µ S, 1413 µ S, 12.88 mS, 111.8 mS) ; maximum 1 per range; manual ( 5 points) ; maximum 1 per range
    Cell Constant 0.1, 1.0, 10.0 ( selectable)
    TDS
    Range .. to 100.0 ppt @ 0.5 fact ( 200.0 ppt @ 1 factor)
    Resolution 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt
    Accuracy ± 1 % full scale
    Cal. Points Manual ( 5 points) ; maximum 1 per range
    TDS Factor 0.40 to 1.00 ( adjustable)
    Temperature
    Range ( Meter) 0.0 to 100.0 º C / 32.0 to 212.0 º F
    Resolution 0.1 º C / 0.1 º F
    Accuracy ± 0.5 º C / ± 0.9 º F
    Coefficient ( Per º C) 0.00 to 10.00 %
    Normalization 15.0 to 30.0 º C ( adjustable)
    Compensation
    Type & Range Automatic with supplied cell or manual
    0.0 to 100 º C / 32.0 to 212.0 º F, 0 to 80 º C / 32.0 to 176.0 º F with supplied cell
    Power Requirements 9 V DC adapter, 1.3 A ( 100/ 240 VAC, SMPS)