    Recalibration unit for automated energy consumption meters UAPS-1 is designed for recalibration of static single-and three-phase power consumption meters, measuring active and reactive energy in two directions.
    The unit is manufactured in three variants:
    - UAPS-1
    - UAPS-1M differs from UAPS-1 by higher output power of voltage and current modules
    - UAPS-1 / P equipped with a universal panel for swift hooking of the recalibrated meters.
    The unit operates automatically under PC control.
    Number of simultaneously recalibrated meters of the same type:
    - 6 three-phase or 18 single-phase meters at UAPS-1and UAPS-1M
    - 6 three-phase or single-phase at the workstations from 1st to 6th, up to 12 single-phase with galvanically coupled series and shunt circuits at workstations from 7th to 18th.
    O Accuracy class of recalibrated meters-0. 5 and less precise by active energy; 1. 0 and less precise-by reactive energy.
    O Accuracy class of recalibrated meters-2. 0 and less precise by active energy at workstations from 7th to 18th ato Accuracy class of recalibrated meters-0. 5 and less precise by active energy; 1. 0 and less precise-by reactive energy.
    O Accuracy class of recalibrated meters-2. 0 and less precise by active energy at workstations from 7th to 18th at UAPS-1 / P unit
    O Rated values of linear 57. 7v and 230V, linear 100V and 400V phase voltage are set within 0. 7-1. 2 of rated value.
    O Outgoing current range at the current module is 0. 001a to 50. 0a for UAPS-1and UAPS-1 / P; 0. 001a to 100. 0a for UAPS-1M
    O Vector maximum power of every voltage and current signal phase is min. 40v*A and 50V*A for UAPS-1and UAPS-1 / P units; min. 80a*V and 150V*A for UAPS-1M.
    UAPS-1provides for
    O Twice quicker recalibration due to automated meter recalibration and adjustment mode exercised under PC control
    O Calculation of meter error, comparing error value to previously set admissible deviations, as well as indication for sorting and rejection.
    O Recalibration of meters' sensitivity and shunt running
    O Generation of meter recalibration protocol as a recordable file that can be printed out.
    O No additional errors as human factor is eliminated from the recalibration process.
    O Rated values of linear 57. 7v and 230V, linear 100V and 400V phase voltage are set within 0. 7-1. 2 of rated value.
    O Outgoing current range at the current module is 0. 001a to 50. 0a for UAPS-1and UAPS-1 / P; 0. 001a to 100. 0a for UAPS-1M
    O Vector maximum power of every voltage and current signal phase is min. 40v*A and 50V*A for UAPS-1and UAPS-1 / P units; min. 80a*V and 150V*A for UAPS-1M.
    Rated phase voltage (Urt) , V 57, 7 and 230
    Rated linear voltage (Urtl) , V 100 and 400
    Operation range of phase voltage 0, 7-1, 2 Urt
    Operation range of phase current, A 0, 001 to 50, 0 or 0, 001 to 100, 0
    Overall dimensions (mm) and weight (KG) of the universal panel, maximum 1520x721x2000 (150)
    Mean time between failure, hours Min. 5000
    Mean lifetime, years Min. 6
    Recalibration interval, years 1