Selamat Datang di
FSUE " Nizhny Novgorod Plant named after M.V. Frunze "

Anggota Gratis
FSUE " Nizhny Novgorod Plant named after M.V. Frunze "
Federasi Rusia
  • Jual

    Three-phase multi-tariff multifunctional electricity (watt-hour) meter SET-4TM.03

    Three-phase multi-tariff multifunctional electricity (watt-hour) meter SET-4TM.03

    Jumlah Pesanan:
    Negara Asal:
    Federasi Rusia
    Used for commercial and technical registration of forward and reverse active and reactive energy and four-quadrant reactive energy consumption in three- and four-wire AC circuits of 3x57.7/100V or 3x120-230/208-400V voltage, 1 to 5A rated current, 10A maximum current, 50Hz frequency.
    Meters have two equally foregrounded galvanically independent RS-485 interfaces and an optical port. Can be used as part of two automated power registration systems simultaneously, or as part of monitoring system. Support ÃÃÃ-4TM.02-compatible protocol.
    Several designs of the meters are possible, varying in accuracy class, rated voltage, number of interfaces and availability of backup supply unit.
    The most complete set includes 4 pulse outputs, two RS-485 interfaces, an optical port, backup supply unit, HASP.
    o Digital processing of incoming analog signal
    o Built-in tarifficator
    o Two equally foregrounded galvanically independent RS-485 interfaces
    o Real-time clock
    o Four galvanically independent configurable pulse outputs
    o HASP
    o Keeping events log, power supply quality log, status log
    o Backup supply unit

    Following parameters can be programmed via / viewed at the RS-485 interface and optical port:
    - rate of exchange by RS-485 channel (disabled for optical port);
    - 1st and 2nd level access passwords;
    - positioning name;
    - network address;
    - voltage and current gain coefficients;
    - power integration period for making load graphs ranging from 1 to 60 minutes by two independent arrays;
    - time synchronization and correction at broadcast query;
    - tariff schedule, schedule for holidays and related days, morning and evening peaks;
    - current time and date;
    - DST adjustment time;
    - programmable flags;
    - indication modes and periods from 1 to 20 sec.;
    - parameters for measuring power supply quality;
    - forward and reverse active and reactive power thresholds;
    - forward active power integration time for comparing with set boundary;
    - masks of current measurement indication modes and basic parameters indication modes.
    o The meters provide for multi-tariff registration of forward and reverse active and reactive energy, as well as four-quadrant reactive energy in 8 tariff zones by 8 day-types in 12 seasons. Tariff zone increment â 10 minutes. Alteration of tariff-zones within 24 hours â up to 144. Tarifficator of the meter considers holidays and related days schedule.

    o Registered forward and reverse active and reactive energy and four-quadrant reactive energy can be displayed at the indicator:
    - total since zero reset;
    - for current and previous year;
    - for current and previous month;
    - for current and previous 24 hours.
    o Registered forward and reverse active and reactive energy and four-quadrant reactive energy can be viewed via connection interfaces:
    - total since zero reset;
    - for current and previous year;
    - at the beginning of current and previous year;
    - for current month and previous 11 months.
    - at the beginning of current month and beginning of each previous 11 month;
    - for current 24-hours and 30 previous 24-hour periods;
    - at the beginning of current and 30 previous 24-hour periods.
    o Two independent power profile arrays can be supported with programmable integration time from 1 to 60 min for forward and reverse active and reactive energy. Each power profile array with integration period of 30 min is stored for 3,7 months.
    o Morning and evening peaks of forward and reverse active and reactive power can be registered for both power profile arrays using 12-seasons schedule.
    o Instantaneous values (integration period is 1 sec.) of the following parameters cab be measured and displayed:
    - active, reactive and vector power per each phase and phase total depending on current and voltage gain coefficients;
    - phase-, inter-phase and positive-phase-sequence voltage;
    - linear current, current waveform distortion factor, forward and reverse series current unbalance factor;
    - each phase power factor and phase sum factor;
    - circuit frequency;
    - phase and inter-phase voltage waveform distortion factors
    - forward and reverse series voltage unbalance factor;
    - temperature inside the meter;
    - time and date.

    Accuracy class for measurement of active/reactive power 0,2S/0,5 or 0,5S/1,0
    Rated current, A 1
    Maximum current, A 10
    Current sensitivity, mA 1
    Rated voltage, V 3x57,7/100 or 3x120â¦230/208â¦400
    Tarifficator:
    8 Tariff zones
    8 Day-types
    12 Seasons
    Number of isolated pulse outputs 4
    Data security at power supply break: For permanent data - 100 years;
    For operational data - 10 years
    Two access levels and hardware protectionof metrological factors memory
    Operation temperatures range, ÃC -40 to +60
    Recalibration period, years 10
    Mean overhaul life, years 30
    Dimensions, mm 330x170x80
    Weight, kg Max. 1,5