Selamat Datang di Indotrade.com
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade
Tahun ke-13
PD. Ninggala Berkat Abadi telp : 021-65866285, 021-32761402, 021-98338008, 081380893620 Fax : 021-65866285 Teknik - Alat Safety - Alat Perkapalan - Agricultural - Lingkungan - Alat Pertanian - Alat Laboratorium - Peralatan Teknik - Alat Uji Ukur - Measuri
http://indotrade.com/ninggalaberkatabadi/
PD. Ninggala Berkat Abadi telp : 021 65866285,  021 32761402,  021 98338008,  081380893620 Fax : 021 65866285 Teknik   Alat Safety   Alat Perkapalan   Agricultural   Lingkungan   Alat Pertanian   Alat Laboratorium   Peralatan Teknik   Alat Uji Ukur   Measuri

menampilkan 20 dari 117

Katalog Produk

Hirayama HG 50-High grade autoclave
HargaTelp : 021-32761402 Fax : 021-65866285 email : ninggalaabadi@yahoo.com
Jumlah Pesanan: Tambah ke Keranjang
Cara PembayaranTransfer Bank (T/T)
Keterangan
Automatic lid opening button replaces a foot pedal.
Automatic lid closing button closes and locks lid conveniently and safely.
New body design with a 50- or 80-liter chamber of larger diameter and shorter height.
Safety interlock senses pressure and temperature and prevents lid from opening when the chamber is
pressurized, temperature is too high, and also during a cycle.
Programmable auto-start for running a cycle up to 99 hours later.
Efficient 15-liter steam condenser eliminates steam exhaust into the lab.
Over-flow lamp indicates that the drain bottle is full and ready to be emptied.
Built-in cooling fan for faster post-sterilization cooling and shorter completion time.
Selectable rate of steam venting after sterilization.
Programmable time for air removal before sterilization.
Large control and display panel improves functionality and shows the progress of the sterilization cycle:

HG-50 specification
Outside Dimensions
( 19.7W x 27.2D x 35.0H) in
( 455W x 691D x 890H) mm
Chamber Dimensions
( 14.3D x 18.2H) in,
( 364D x 482H) mm
Chamber Volume
50L working, 60.0L actual
Temperature Range
105° C to 135° C
Sterilization Timer
1 to 300 minutes
Media Warming/ Holding Temperature
Programmable at 45° C to 60° C to keep media warm up to 24 hours
Auto-Start Timer
Initiate a cycle 1 to 99 hours later
Cooling Fan Switch
to turn fan on or off
Air Removal Timer
Programmable, 3 to 9 minutes after temperature has reached 97° C
Steam Venting
Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock
Programmable, 60° C to 97° C for greater safety and flexibility
Sterilization Program Cycles
1) Liquid cycle, 2) Agar ( liquid with warming) cycle, and 3) Solid cycle
Additional Cycle for Agar Dissolution
Cycle for dissolving and keeping agar warm ( no sterilization)
Agar Dissolution Protocol
Initially at 60° C-100° C for 1-60 min, then at 45° C-60° C for up to 24 hours.
Safety Features
Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure
power cut-off, safety valve ( 0.26MPa gauge) , sensor for improper lid closing
Steam Condenser
15-liter water tank
Drain Water Bottle
2 liters
Power Requirements
120V or 220V( specify required voltage) , 50/ 60 Hz, single phase
Power Consumption
2.0 kilowatts ( optional 2.7 kilowatt at 220V only)
Shipping Weight
HG-50 154 lb ( 70 kg)
HG-80 207 lb ( 85 kg)