FLUKE 744 Documenting Process Calibrator
Keterangan
The 744 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 744 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
⢠Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
⢠Source/ simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
⢠Power transmitters during test using loop supply with simultaneous mA measurement
⢠Measure/ source pressure using any of 29 Fluke 700Pxx Pressure Modules
⢠Create and run automated as-found/ as-left procedures to satisfy quality programs or regulations. Record and document results
⢠Holds up to a full week of downloaded procedures and calibration results.
⢠Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
⢠Easy to use
⢠Three year warranty
⢠Bright white dual display. Read both sourced and measured parameters simultaneously.
⢠Multi lingual interface
⢠Rechargeable NiMH battery for 10 hour uninterrupted use. Includes gas gauge.
⢠Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
⢠Delivered with DPC/ Track Sample software.
⢠Compatible with many Asset Management software packages.
HART Capabilities
The 744 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 275 HART communicator.
⢠Requires no external box or second tool for everyday HART calibration and maintenance.
⢠Offers fast HART communication.
⢠Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
⢠Works with multiple masters, burst mode, and multi-drop configurations.
⢠Is easy to update as additional instruments are added and new HART versions are released.
⢠Interrogate to determine device type, manufacturer, model, tag.
⢠Reconfigure the sensor mapping of dual sensor temperature transmitters.
⢠Read HART PV function and smart transmitter digital output while measuring analog mA output.
⢠Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
⢠Re-label smart transmitters by reading and writing to the HART tag field.