Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotrade.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Jual

KOEHLER K15600 Tag Open-Cup Flash Tester[4 Jun. 2011, 2:16:10]
HargaInquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalAmerika Serikat
Test Method
For determination of flash and fire points of liquids at temperatures of up to 325° F ( 163° C) and flash points of cutback asphalts at temperatures of less than 200° F ( 93° C) .

Features and Benefits
• Conforms to ASTM D1310, D3143 specifications

• Choice of gas or electrically heated

K15600 Tag Open-Cup Flash Tester
Determines Tag Open-Cup flash point of liquid products and cutback asphalts. Includes sample test cup, plated brass liquid bath with constant level overflow, pivoting ignition taper with pilot light and reference bead, pivoting thermometer holder, heater and cast aluminum base.

Electrically heated model is equipped with stepless variable heat control for accurate control of temperature rate of rise per specifications. Also available with gas or burner.

Specifications
Conforms to: ASTM D1310, D3143

Electrical Requirements
115V 50/ 60Hz, Single Phase, 13A
220-240V 50/ 60Hz, Single Phase, 0.6A

Included Accessories
Pyrexâ„¢ Sample Cup

Dimensions lxwxh, * in.( cm)
10x7x17 ( 25x18x43)
* with thermometer inserted
Net Weight: 7.5 lbs ( 3.4kg)

Shipping Information
Shipping Weight: 9.5 lbs ( 4.3kg)
Dimensions: 1.3 Cu. ft.

Ordering Information
Catalog
Number Product Description Electrical Requirements
K15600 Electrically Heated Model 115V 50/ 60Hz
K15670 Electrically Heated Model 220-240V 50/ 60Hz
K15690 Gas Heated Model

Accessories
Catalog
Number Product Description Temperature Range
250-000-33F ASTM 33F Thermometer -36.5 to + 107.5° F
250-000-33C ASTM 33C Thermometer -38 to + 42° C
250-000-09F ASTM 9F Thermometer 20 to 230° F
250-000-09C ASTM 9C Thermometer -5 to + 110° C
250-000-35F ASTM 35F Thermometer 194 to 338° F
250-000-35C ASTM 35C Thermometer 90 to 170° C
K15610 Leveling Device
For proper adjustment of sample level in test cup. Meets ASTM specifications. Polished aluminum.
K15620 Draft Shield
K15520 Sample Cup