Jual

KOEHLER K14600 Tag Closed Cup Flash Tester
HargaInquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalAmerika Serikat
Test Method
For flash point determinations of liquids with a viscosity of below 5.5 centistokes ( cSt) at 104° F ( 40° C) or below 9.5cSt at 77° F ( 25° C) , and a flash point below 200° F ( 93° C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids.

Features and Benefits
• Conforms to ASTM D56 and related specifications

• Gas or electrical heating

K14600 Tag Closed Cup Flash Tester
Determines flash points of liquid products by the Tag Closed Cup method. Features stepless variable heat control with reference dial for accurate repeat setting of temperature rate of rise per specifications. Also available with gas burner instead of electric heater. Precision machined cover mechanism simultaneously opens slide shutter and applies test flame to sample at the turn of a knob. Includes liquid bath with constant level overflow, brass test cup, plated brass thermometer ferrules and test flame reference bead. Bath and cover mechanism are constructed of plated brass. Heater is enclosed in a cast aluminum base assembly.

Specifications
Conforms to: ASTM D56; IP 304; FTM 791-1101

Electrical Requirements
115V 50/ 60Hz, Single Phase, 1.3A
220-240V 50/ 60Hz, Single Phase, 0.6A

Included Accessories
Brass Test Cup
Cover Assembly ( includes Slide Shutter, Burner and Thermometer Ferrules)

Dimensions lxwxh, * in.( cm)
5x5x16 ( 13x13x41)
* with thermometers inserted
Net Weight: 7 lbs ( 3.2kg)

Shipping Information
Shipping Weight: 8 lbs ( 3.6kg)
Dimensions: 0.76 Cu. ft.

Ordering Information
Catalog
Number Product Description Electrical Requirements
K14600 Electrically Heated Model 115V 50/ 60Hz
K14670 Electrically Heated Model 220-240V 50/ 60Hz
K14690 Gas Heated Model

Accessories
Catalog
Number Product Description Temperature Range
250-000-09F ASTM 9F Thermometer 20 to 230° F
250-000-09C ASTM 9C Thermometer -5 to + 110° C
250-000-57F ASTM 57F Thermometer -4 to + 122° F
250-000-57C ASTM 57C Thermometer -20 to + 50° C
K14510 Cover Assembly
Includes slide shutter burner and thermometer ferrules
K14520 Brass Test Cup