Anggota Gratis 
Bahasa :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indotrade.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Informasi Kontak
Nama:
Ibu REGINA / VANNY / VITHA [Direktur/CEO/Manajer Umum]
E-mail:
Situs Web:
Pesan Instan:
Y!: andalan1974@yahoo.com 
Nomor Telpon:
Nomor telpon Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Ponsel:
Nomor ponsel Ibu REGINA / VANNY / VITHA di JAKARTA
Nomor Faks:
Nomor faks Ibu REGINA / VANNY / VITHA di JAKARTA
Alamat:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan

Jual

KOEHLER HKV3000 and HKV4000 High Temperature Kinematic Viscosity Baths with Integrated Digital Timing
HargaInquiry
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 unit
Negara AsalAmerika Serikat
Test Method
Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.

Features and Benefits
• Microprocessor control of temperature between ambient and 232° C ( 450° F) , and down to – 20° C ( – 4° F) with an external chiller

• Integrated digital timing for convenient measurement of sample efflux times

• HKV4000 model permits entry of viscometer constants for automatic calculation and display in viscosity units or seconds

• Dual digital displays show setpoint and actual bath temperature

• Selectable temperature scale - Fahrenheit or Celsius

• Integrated redundant over-temperature and low liquid level cut-off circuitry

• Conforms to ASTM D445, D2170 and related specifications for kinematic viscosity testing

Click on the image to view a larger photo of the instrument.

--------------------------------------------------------------- -----------------
HKV3000 and HKV4000 High Temperature Kinematic Viscosity Baths
Constant temperature bath series with advanced temperature control circuitry and integrated timing features for convenient, accurate glass capillary viscometry determinations. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual digital displays permit easy setting and monitoring of bath temperature. Two place calibration offset capability is provided. Baths accommodate seven glass capillary viscometers of various types. Viewing the viscometers is made easy by glare-free fluorescent illumination inside the bath and a baffle that provides a background for easy viewing. Temperature control uniformity is assured by means of motorized stirrer which provides complete circulation without turbulence. Connection of the built-in cooling coil to tap water or a recirculating water chiller facilitates temperature control at ambient or below ambient temperatures. Communications software ( RS232, etc.) ramp-to-set, and other enhanced features are available at additional cost. Contact your Koehler Customer Service representative for more information.

Integrated Timing Features — HKV3000 incorporates seven digital timers on the front control panel for convenient timing and monitoring of the efflux interval for each viscometer. On HKV4000, the user can enter the viscosity constant for each viscometer on the front LCD control/ display, and then get the test result in both efflux time and viscosity units automatically after stopping each timer. All timing functions on both models are displayed in 0.01 second resolution and are accurate within 0.01% .

Bath Construction and Safety Features — Bath chamber is a clear Pyrex vessel enclosed in a polyester-epoxy finished steel housing. Top working surface has seven 2" ( 51mm) viscometer ports and is constructed of stainless steel for easy cleaning. Front viewing window assures safe, distortion-free viewing. Microprocessor temperature controller incorporates safety circuitry that interrupts power to the heaters in the event of an over-temperature condition or disconnection of the primary probe. For added safety, a redundant adjustable controller with separate sensor probe interrupts power if an over-temperature situation occurs. An integrated low-liquid sensor prevents operation of the bath if the bath liquid is not filled to the proper level, and cuts off power should it fall below during operation. Both over-temperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed. Bath rests on adjustable leveling feet. All electronics are mounted on a sliding tray for easy access. Includes thermometer holder and seven plastic port covers with handles.

Specifications
Conforms to the specifications of: ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100

Temperature Range: ambient to 232° C ( 450° F) ; – 20° C to 232° C ( – 4° F to 450° F) with an external chiller

Temperature Control Display: 0.1° C/ ° F resolution, calibrate to 0.01° C/ 0.01° F

Temperature Control Accuracy and Uniformity: Exceeds ASTM requirements throughout the operating range

Integrated Timing:
HKV3000 — Seven individual start/ stop timers with displays to 0.01 seconds, accurate to within 0.01%
HKV4000 — Seven start/ stop buttons with integrated LCD display, retention of viscometer constant, automatic calculation and display in viscosity units or seconds to 0.1 seconds, accurate to within 0.01% .

Communication: RS232 port included with HKV4000 ( optional for HKV3000)

Viscometer Ports: Seven round 2" ( 51mm) ports

Bath Medium: Water or suitable heat transfer fluid

Bath Capacity: 5.8 gal ( 22L)

Bath Depth: 12" ( 31cm)

Electrical Requirements
115V, 50/ 60Hz, Single Phase, 12.7A
220-240V, 50/ 60Hz, Single Phase, 7.3A

Included Accessories
Port Covers, Delrin® ( 7)
Thermometer holder

Dimensions lxwxh, in.( cm)
20x15x24 ( 51x39x62)
Net Weight: 83 lbs ( 38kg)

Ordering Information
Catalog
Number Model Electrical Requirements Bath
Depth Bath
Capacity Dimensions
Ixwxh, in.( cm) Net
Weight
K23800 HKV3000 115V, 50/ 60Hz
Single Phase, 12.7A 12"
( 31cm) 5.8 gal
( 22 L) 20x15x24
( 51x39x62) 84 lbs
( 38kg)
K23802 HKV4000 115V, 50/ 60Hz
Single Phase, 12.7A 12"
( 31cm) 5.8 gal
( 22 L) 20x15x24
( 51x39x62) 84 lbs
( 38kg)
K23890 HKV3000 220-240V, 50/ 60Hz
Single Phase, 7.3A 12"
( 31cm) 5.8 gal
( 22 L) 20x15x24
( 51x39x62) 84 lbs
( 38kg)
K23892 HKV4000 220-240V, 50/ 60Hz
Single Phase, 7.3A 12"
( 31cm) 5.8 gal
( 22 L) 20x15x24
( 51x39x62) 84 lbs
( 38kg)