KYORITSU 5410[19 Mar. 2009, 0:49:54]
Keterangan
⢠Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at à 1/2 Range, measuring RCD trip time at à 1 and à 5 Ranges.
⢠Measurement of trip out current
Measuring trip out current by varying current automatically.
⢠Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
⢠Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range. ⢠Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
⢠Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC 60529 IP54).
⢠Backlight
Facilitating working at dimly illuminated locations.
Measurement of RCD trip time - Measurement of trip out current :
Range : Ã5 Ã1 Ã1/2 AUTO RAMP (mA)
Rated Voltage : 100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current : 15/30/50/100mA 15/30/50/100/200/500mA 15/30/50/100/200/500mA
Measuring range : Testing time
200ms Testing time
2000ms Testing time
2000ms 40%~110% of lân
(goes up by 5%)
Testing time
300ms à 15steps
Accuracy
(Trip Time) : ±1%rdg±3dgt ±1%rdg±3dgt ±1%rdg±3dgt Test Current
at each step
-4%~+4%
Accuracy
(Test Current) : +2%~+8%dgt +2%~+8%dgt |-8%~-2%dgt
Voltage Measurement :
Measuring range : 80V~450V (50/60Hz)
Accuracy : ±2%rdg±4dgt
Applicable Standard : IEC 61010-1 Pollution degree2 CAT.III 300V / CAT.II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display : 1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity : 0ºC~40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity : -20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage : AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance : 50M© or more / 1000V (between electrical circuit and enclosure)
Sleep Function : (1) Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2) Backlight turns off in 1 minute after it lights up.
Power Source : DC 12V / Size AA battery R6P (SUM-3) Ã 8 pcs.
Dimension : 186(L)Ã167(W)Ã89(D)mm
Weight : Approx. 965g (including batteries)
Possible number of Measurements 1200 times or more
(measure every 30 seconds at Ã1/2 Range, lân=100mA)
Accessories : 7128 (Test lead)
7129 (Test lead with alligator clip)
8017 (Long pin) Ã 2
Cord case, Strap belt, Instruction manual,
Size AA battery R6P(SUM-3)Ã8pcs.