Keterangan
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
Insulation Resistance :
- Test Voltage : 250V/500V/1000V
- Measuring Ranges
(Mid-scale Value) : 20M©/200M©/2000M©
- Output Voltage
on open circuit : Rated test voltage+20%, -0%
- Nominal Current : 1mA DC min.
- Output Short
Circuit Current : 1.5 mA DC approx.
- Accuracy : ±1.5%rdg±5dgt (20M©/200M©)
±10%rdg±3dgt (2000M©)
Continuity Test :
- Measuring Ranges
(Mid-scale Value) : 20©/200©/2000©
- Output Voltage
on open circuit : 7~12V DC
- Measuring Current : 200mA DC min.
- Accuracy : ±1.5%rdg±5dgt (20©)
±1.5%rdg±3dgt (200©/2000©)
AC Voltage:
- AC Voltage range : 0-600V AC
- Accuracy : ±5%rdg±3dgt
General :
- Safety Standard : IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
- IP Rating : IEC 60529-IP54
- EMC Standard : IEC 61326-1
- Withstand Voltage : 3700V AC for 1 minute
- Power Source : R6P (AA) (1.5V) × 8
- Dimensions : 185(L) × 167(W) × 89(D)mm
- Weight : 990g approx
- Accessories : 7122 (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6P (AA) × 8
Shoulder Strap
Instruction Manual