HIOKI 8206-10 MICRO HiCORDER[6 Mar. 2009, 1:48:08]
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Kemas & Pengiriman1 Unit
Negara AsalJepang

Keterangan

Successor to the long-popular MICRO HiCORDER 8203
True RMS Voltage and Current Recorders with Multimeter Operability!

The MICRO HiCORDER 8206-10 incorporate the latest technology in HIOKI's best selling MICRO HiCORDER 8200 series. Maintaining the operational simplicity of an analog multimeter, these data recorders offer easy to use features such as :

- Direct current measurement of up to 1000A
- Fast LCD level meter vs. a stylus to quickly display the measured level
- True RMS rectification system to accurately read distorted waveforms
- Climate-resistant recording paper for easy readability and durability
- Sampling rate of 100 samples/second with selectable chart speeds
- The 8206-10 has two channels for recording of AC voltage and AC current simultaneously

Basic specifications :

Measurement ranges : AC Voltage: 100/200/500 V f.s. 3 ranges
AC Current: 10 A to 100 A AC 4 ranges (with optional CLAMP ON SENSOR 9650)
10 A to 500 A AC 6 ranges (with optional CLAMP ON SENSOR 9651)
10 A to 1000 A AC 7 ranges (with optional CLAMP ON SENSOR 9668)
Sampling period : 10 ms
Frequency characteristic : AC/DC voltage range:
+0.5 dB to -3 dB from 30 Hz to 30 kHz.
AC current range:
Frequency characteristic is determind by the clamp sensor.
Paper feed speed : 60 cm/hour to 2 cm/hour, 5 ranges
Number of input channels : 1 channel AC voltage and 1 channel AC current
(Simultaneous recording based on two channel alternating sampling, for commercial power lines, input is voltage isolated.)
Accuracy : Voltage: ±2 % f.s. (45 Hz to 66 Hz),
Current: ±3.53 % f.s. (used with CLAMP ON SENSOR 9651 / option, AC 500 A range)
Power supply : 100 to 240 V AC (50/60 Hz) or 9.5 to 14 V DC, 2 way
Dimensions, mas : 250 mm(9.4 in)W × 122 mm(4.8 in)H × 93.5 mm(3.66 in)D, 1.2 kg (42.33 oz)
Accessories : Recording paper 9235 (1 roll), roll paper holder (2), Power cord (1), CONNECTION CORD 9257 (1), CARRYING CASE 9344 (1)