TLSM laser diameter measuring instrument [ 18 Jan. 2011, 20:05:00 ]
Keterangan
TLSM laser diameter measuring instrument TLSM Laser diameter measuring instrument is a kind of non-contact measuring meter with high accuracy and to be used to measure dimensions. It obtains the dimensions of measured target via laser beam scanning.caliper meter can be widely used to measure objects hot, soft, friable as well as not easy to be measured with other traditional methods, especially, suited to online measurement in the production of wire rod, bar, tubing, mechanical and electronic elements.
The automatic mode of caliper meter is applied in continuous measurement and manual mode does in single time or continuous measurement. Caliper meter can be set in some respects, i.e. up and low limits, Max.- Min. limit and corresponding warning for overrun; It can also calculate maximum, minimum and average values, e.g. to measure maximum and minimum values of a rotary cylinder, deviation of a roller as well as similar dimensions.
Technical Specifications
Type
7 digitals LED digitron
Measuring range Accuracy of measurement duplicability Resolution ratio
TLSM101
0.01-1
0.001
0.0005
0.0001
TLSM110
0.1-10
0.002
0.0005
0 .0001
TLSM130
0.6-30
0.003
0.0005
0.0001
Characteristics
Display mode 7 digitals LED digitron
Beam scanning speed 1680 times/ sec
Measured dimensions external diameter and seam( 12 data can be measured simultaneously at most)
Measuring modes automatic and manual( incl. key board trigger and external trigger, host control)
Measuring initial trigger internal continuous trigger, keyboard trigger and external trigger; Min. short circuit signal 30ms is required or a low level signal with collector open-circuit is supplied for external trigger.
Host interface RS-232C( optional for RS-485)
Analog interface Output is the difference between measure value and nominal; value, with + 10V to -10V corresponding to + 2mm to -2mm
Resolution ratio 0.1µ m, 5mv/ 1µ m
Statistical calculation average value, Maximum, Minimum, Mix.-Min. from measurement start to measurement termination
Tolerance setting
Normal 7digitals at most
Up-limit 7 digitals at most
Low-limit 7 digitals at most
Max-Min 7digitals at most
Offset value 7digitals at most
Warning overrun warning for Up and Low limits, and Mix.-Min
Contactless switch 1a* 3( 0.1A, AC100V)
Measurement of transparent object available
Working atmosphere 0C-45C; 35/ 100-85/ 100RH( dewless)
Power supply AC85V-265V; 50Hz/ 60Hz
Power 30W
Weight control unit: 3kg; sensor: 2kg
Dimensions control unit: 310mmX240mmX85mm
sensor: 420mmX110mmX35mm
Standard delivery
Description
Quantity
Description ;
Quantity
sensor sender
1
control unit
1
sensor receptor
1
signal cable
2
sensor base
1
supply cord
1