    Hanna Portable EC TDS NaCl ° C Meter HI 9835

    [18 Dec. 2011, 23:41:42]
    Hanna Portable EC TDS NaCl ° C Meter HI 9835
    Jumlah Pesanan
    Tambah ke Keranjang
    Cara Pembayaran
    Transfer Bank (T/T)
    Kenalkan ke teman Anda Masukan ke Produk Rekanan

    Keterangan

    Portable EC/ TDS/ NaCl/ ° C Meter HI 9835
    Mfg : HANNA
    Descrription :
    Autoranging, manual ranging and range lock
    Four ring probe design
    Automatic, manual and no Temperature Compensation
    Auto endpoint; Automatically freezes stable readings on the LCD display
    GLP features
    BEPS; ( Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
    On-screen user guides
    Backlit display
    % Battery displayed on startup

    Specifications :
    Range : EC : 0.00 to 29.99 µ S/ cm; 30.0 to 299.9 µ S/ cm; 300 to 2999 µ S/ cm; 3.00 to 29.99 mS/ cm;
    30.0 to 200.0 mS/ cm; up to 500.0 mS/ cm ( actual EC) *
    TDS : 0.00 to 14.99 mg/ L ( ppm) ; 15.0 to 149.9 mg/ L ( ppm) ; 150 to 1499 mg/ L ( ppm) ; 1.50 to
    14.99 g/ L ( ppt) ; 15.0 to 100.0 g/ L ( ppt) ; up to 400.0 g/ L ( ppt) ( actual TDS) * with 0.80
    conversion factor
    NaCi : 0.0 to 400.0%
    Temperature : â 20.0 to 120.0 º C ( -4.0 to 248.0º F)
    Resolution : EC : 0.01 µ S/ cm; 0.1 µ S/ cm; 1 µ S/ cm; 0.01 mS/ cm; 0.1 mS/ cm
    TDS : 0.01 mg/ L ( ppm) ; 0.1 mg/ L ( ppm) ; 1 mg/ L ( ppm) ; 0.01 g/ L ( ppt) ; 0.1 g/ L ( ppt)
    NaCi : 0.10%
    Temperature : 0.1° C
    Accuracy @ 25° C : EC : ± 1 % of reading ( ± 0.05 µ S/ cm or 1 digit)
    TDS : ± 1 % of reading ( ± 0.03 mg/ L ( ppm) or 1 digit, whichever greater)
    NaCi : ± 1% of reading
    Temperature : ± 0.2° C ( excluding probe error)
    Calibration : EC : automatic, one point with six memorized values ( 84, 1413, 5000, 12880, 80000, 111800 µ S/ cm)
    NaCi : one point with HI 7037 calibration solution
    Temperature : two point, at 0 and 50° C ( 32 and 122° F)
    Temperature : automatic or manual from â 20.0 to 120.0 º C ( -4.0 to 248.0º F) ( can be disabled for
    Compensation measuring conductivity)
    Temperature : selectable from 0.00 to 6.00% / º C ( EC and TDS only) ; default value is 1.90% / º C
    Coefficient
    TDS Factor : selectable from 0.40 to 0.80 ( default value is 0.50)
    Probe : HI 76309 four ring conductivity probe with internal temperature sensor, DIN connector
    and 1 m ( 3.3â ) cable ( included)
    Power Supply   : 1.5V AAA batteries ( 3) / approximately 200 hours of continuous use without backlight
    ( 50 hours with backlight on) ; auto-off after 5, 10, 20 and 60 minutes ( can be disabled)
    Environment : 0 to 50° C ( 32 to 122° F) ; RH max 95%
    Dimensions : 185 x 72 x 36 mm ( 7.3 x 2.8 x 1.4â )
    Weight : 300 g ( 10.6 oz)