Selamat Datang di Indotrade.com
Masuk | Daftar
Anggota Prioritas Prioritas Indotrade
Tahun ke-13
CV. DUTA MEDICA SARANA
CV. DUTA MEDICA SARANA
http://indotrade.com/dumedpower/
DI JUAL - BLOOD GAS ANALYZER GASTATE LENGKAP KONDISI SEKEN HARGA NEGO - EX RUMAH SAKIT SWASTA - KONDISI MULUS (0813-1590-4286)
Informasi Kontak
Nama:
Tn. Fuad Ahmad
[Pemasaran]
E-mail:
Situs Web:
Pesan Instan:

Nomor Telpon:
Nomor telpon Tn. Fuad Ahmad di Jakarta Pusat
Nomor Ponsel:
Nomor ponsel Tn. Fuad Ahmad di Jakarta Pusat
Nomor Faks:
Nomor faks Tn. Fuad Ahmad di Jakarta Pusat
Alamat:
RSPAD GATOT SOEBROTO. (Wartel RSPAD Gatot Soebroto, Samping radiologi) Jl. KH. Abdul Rahman Saleh No.24 - Senen Telp : 021 34834914/94522310
Jakarta Pusat, Jakarta
Indonesia
ALAT KESEHATAN, DUTA MEDIKA SARANA, HOSPITAL ONLINE STORE
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Jual

INFANT INCUBATOR YP100A " DAVID NINGBO" by : dumedpower[20 May. 2010, 5:47:21]
Harga30.500.000,-
Jumlah Pesanan:
Kemas & PengirimanUNIT
Negara AsalChina
INFANT INCUBATOR YP100A " DAVID NINGBO"
INFANT INCUBATOR State Food and Drug Administration 2005 No.: 3540651 CMDC TUV ISO9001 ISO13485 CE0123
Brief introduction: servo-controlled by micro-computer; quite operation windows can reduce the disturbance to the baby during nursing; touch switch panel with LED digital display, set-temp, real-temp are displayed separately; multiply self-checking alarms with audible and  visible; heating power rate indicates 0-100% ; the infant bed can be pulled out from the side door Standard configure: Hood, infant bed, temperature controller, water tank, air filter, I.V. Pole, stand.  Technical specification: Power supply : AC220V 50HZ Power input: 600VA Air Temperature control range 25 ~ 37 Changing of temperature: d0.5 Uniformity of temperature: d0.8 Temperature rising time: d45min Noise level: d55dB A   Alarming: audible and visible alarm indication, and it can indicate the real temperature and cut off  the power supply of heater. Over-temp alarm: when the temperature control d38  Deviation alarm: ± 3  Sensor alarm: when the sensor is disconnected, open circuit, short circuit or put on the wrong place; Fan alarm: when the fan is blocked, speed d1000rpm or stop working; Power failure alarm: when there is no power or the power cord is disconnected. System alarm: when there is E2ROM malfunction inside of temperature controller. Package: Gross Weight 72Kg Measurement 1085mm× 640mm× 1065m
Kenalkan ke teman Anda
Anda mendapat [3] permintaan baru.
Ke Menu Anggota
Depan - Penawaran Dagang - Daftar Produk - Daftar Permintaan - Daftar Kerjasama - Daftar Perusahaan
© 2024 Indotrade.com. Hak Cipta Dilindungi Undang-undang.